1.
Enter the schedule number (01-20) and time
window number (01-20),
and note the day of the
week the action is desired.
2.
Enter the code for the desired action and
action specifier.
The action codes represent the
events that are to take place when the scheduled
time is reached. Each action also requires an
action specifier, which defines what the action will
affect (relay, relay group, partition, zone list, user
group). The action specifier varies, depending on
the type of action selected.
The following is a list of the Action Codes (desired
actions) used when programming Time-Driven
events. Note that these codes are independent of
the relay codes programmed during
Output
Programming
in the
#93 Menu Mode
.
Relay Commands
Action Code
Action
Action Specifier
01
Relay On
Relay #
02
Relay Off
Relay #
03
Relay Close for 2 seconds
Relay #
04
Relay Close XX minutes (set
in field 1*74)
Relay #
05
Relay Close YY seconds (set
in field 1*75)
Relay #
06
Relay Group On
Relay Group #
07
Relay Group Off
Relay Group #
08
Relay Group Close for 2
seconds
Relay Group #
09
Relay Group Close XX
minutes (set in field 1*74)
Relay Group #
10
Relay Group Close YY
seconds (set in field 1*75)
Relay Group #
Arm/Disarm Commands
Action Code
Action
Action Specifier
20
Arm-STAY
Partition(s)
21
Arm AWAY
Partition(s)
22
Disarm
Partition(s)
23
Force Arm STAY (Auto-
bypass faulted zns)
Partition(s)
24
Force Arm AWAY (Auto-
bypass faulted zns)
Partition(s)
25
Arm INSTANT
Partition(s)
26 Arm
MAXIMUM
Partition(s)
•
The auto-arm warning (field 2*06) applies
when using Time-Driven events to auto-arm.
•
Temporary schedules do not override an
auto-arming or auto-disarming programmed
in Time-Driven events.
•
The
auto-arming window cannot be extended
using the Installer Code + #82 Mode.
Bypass Commands
Action Code
Action
Action Specifier
30
Auto bypass – Zone list
Zone list #
31
Auto unbypass – Zone list
Zone list #
Open/Close Windows
Action Code
Action
Action Specifier
40
Enable Opening Window by
partition
Partition(s)
41
Enable Closing Window by
partition
Partition(s)
42
Enable Access Window for
access group
Access Group
Access Control Commands
Action Code
Action
Action Specifier
55
Access Point Grant
Access Point #
56
Access Point Grant with
Override
Access Point #
57
Access Point Protect
Access Point #
58
Access Point Bypass
Access Point #
59
Access Point Lock
Access Point #
60
Access Point Exit
Access Point #
61
Access Point Group Grant
Group #
62
Access Point Group Grant
with Override
Group #
63
Access Point Group Protect
Group #
64
Access Point Group Bypass
Group #
65
Access Point Group Lock
Group #
66
Access Point Group Exit
Group #
67
Access Point Partition Grant
Partition #
68
Access Point Partition Grant
with Override
Partition #
69
Access Point Protect by
Partition
Partition #
70
Access Point Bypass by
Partition
Partition #
71
Access Point Lock by
Partition
Partition #
72
Access Point Exit by Partition
Partition #
73
Access Point Trigger On
Trigger #
74
Access Point Trigger Off
Trigger #
77
Access Point Group Enable
Group #
78
Access Point Group Disable
Group #
Содержание VISTA-128BPEN
Страница 2: ......
Страница 10: ......
Страница 58: ...Vista 128BPEN Installation and Setup Guide 3 38 ...
Страница 82: ...Vista 128BPEN Installation and Setup Guide 5 14 ...
Страница 102: ...Vista 128BPEN Installation and Setup Guide 8 2 ...
Страница 118: ...Vista 128BPEN Installation and Setup Guide C 2 ...
Страница 126: ......