Vista-128BPEN Installation and Setup Guide
3-30
•
If touch-tones are not present following phone access to the security system
via an on-premises phone, try
reversing the pair of wires connected to terminals 3 and 4 on the 4286.
•
If the phone plug is disconnected from the control, the premise’s phones will not operate.
YELLOW
NO CONNECTION
RED
BLACK
GREEN
TO CONTROL PANEL
KEYPAD CONNECTIONS
KEYED
HEADER
12
3
4
5
6
7
NO
CONNECTION
4286 VIP MODULE
ANSWERING
MACHINE
PREMISES
ANSWERING
MACHINE AND
PHONES
TIP
RING
RJ31X
JACK
TIP
RING
INCOMING TELCO LINE
CALLER ID
UNIT
IMPORTANT NOTE FOR EXISTING INSTALLATIONS:
EXISTING WIRES CONNECTED TO THE “HANDSET”
TERMINALS ON CONTROL MUST BE MOVED FROM
THERE TO TERMINALS 3 AND 4 ON THE 4286.
U.S. PATENT No. 4791658
THIS DEVICE COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION No. AC3USA-74659-KX-N
RINGER EQUIVALENCE: 1.0B
FOR COMPLETE INFORMATION, SEE INSTALLATION
INSTRUCTIONS N6431-3 ACCOMPANYING 4286 VIP
MODULE
GREY
BROWN
GREEN
RED
EARTH
GROUND
TIP RING TIP RING
4500
THERMOSTAT
GREEN
YELLOW
HANDSET INCOMING
TELCO LINE
NOTE:
4286 DEVICE
ADDRESS IS
FACTORY SET
TO “4”
SEE SPEAKER NOTE
SPEAKER NOTE:
IF CONNECTING SINGLE SPEAKER, USE 8-ohm SPEAKER ONLY.
IF CONNECTING 2 SPEAKERS, USE 4-ohm or 8-ohm SPEAKERS
AND
CONNECT IN SERIES.
SPEAKER
VOLUME
CONTROL
4286_wiring-002-V1
Figure 3-33: VIP Module Connections
Installing the Audio Alarm Verification Module
UL
Audio Alarm Verification (AAV) is not permitted in UL installations.
•
Contact ID code for “Listen-in to Follow” is 606. Contact ID is the only reporting format that will send a “Listen-in
to Follow.” It is the only format capable of uniquely reporting all 128 zones, as well as openings and closings for
all 150 users. This requires central stations to be equipped with the MX8000 receiver to fully support all new
VISTA-128BPEN report codes. If you need to update your MX8000 receiver, contact your distributor.
•
If you are also using a 4286 VIP Module, be sure to follow
Figure 3-34 when making connections.
The UVS consists of a UVCM and at least one UVST. The UVCM board has a DC power jack and a 34-position terminal
block for making connections to a DC power source, UVSTs, telephone lines, music source, or to the 4286 VIP Module;
and to a control panel’s voice trigger and bell outputs (if required). Refer
Figure 3-34
for wiring connections. For a
detailed explanation of the wiring connections and the functions of the DC power jack and terminal block positions, refer
to the installation instructions that accompany the UVS.
Содержание VISTA-128BPEN
Страница 2: ......
Страница 10: ......
Страница 58: ...Vista 128BPEN Installation and Setup Guide 3 38 ...
Страница 82: ...Vista 128BPEN Installation and Setup Guide 5 14 ...
Страница 102: ...Vista 128BPEN Installation and Setup Guide 8 2 ...
Страница 118: ...Vista 128BPEN Installation and Setup Guide C 2 ...
Страница 126: ......