UV100E ULTRAVIOLET SYSTEMS

3

68-0262—5

Temperature Ratings:

Ambient Temperature Range: 30°F to 104°F (-2°C to 40°C).

Bulb Temperature Range (In Moving Air): 30°F to 140°F 

(-2°C to 60°C).

Relative Humidity: 

Up to 95% rh, non-condensing.

Dimensions:

See Fig. 3.

Approvals:

Underwriters Laboratories: File no. E223009

The health aspects associated with the use of this product and 

its ability to aid in disinfection of environmental air have not 

been investigated by UL.

INSTALLATION

When Installing this Product…

1.

Read these instructions carefully. Failure to follow them 

could damage the product or cause a hazardous 

condition.

2.

Check the rating given in the instructions and on the 

product to make sure the product is suitable for your 

application.

3.

Installer must be a trained, experienced service 

technician.

4.

After installation is complete, check out product 

operation as provided in these instructions.

WARNING

UV Light Hazard. 

Harmful to bare skin and eyes. 

Can cause temporary or permanent loss of vision.

View illumination only through lamp light indicator on 

lamp handle.

To prevent exposure to ultraviolet light, disconnect 

power to ultraviolet system before servicing any part of 

heating and air conditioning system.

Do not mount device in location that allows ultraviolet 

light to be seen after installation.

Do not attempt to bypass duct mount switch.

CAUTION

Personal Injury Hazard. 

Power supply can cause electrical shock.

Disconnect power supply before beginning installation. 

Do not open base unit or lamp handle; there are no 

user-serviceable components inside.

Selecting Mounting Location

CAUTION

Equipment Damage Hazard. 

Ultraviolet light can cause color shift or structural 

degradation of plastic HVAC materials.

Select mounting location that prevents exposure to 

plastic components with 

unknown resistance to 

ultraviolet light.

 Three-feet minimum is recommended 

between ultraviolet lamp and plastic-fabricated devices 

(such as humidifiers and non-fiberglass media filters).

Depending on installation location, the UV System can operate 

as an Air Treatment System or as a Surface Treatment 

System.

Air Treatment System

Installed in the return air duct, the Air Treatment System kills a 

high percentage of airborne germs circulating through the 

forced air heating and cooling system. Individual results 

depend on careful installation and maintenance and on the 

actual amount of time the system fan operates. See Fig.1.

Fig. 1. Typical Air Treatment System installations.

M22857

WARNIN

G/AVER

TISSEM

ENT

!

Nocifs p

our la p

eau nue 

et les 

Veuillez lire 

et bien com

prendre 

l’install

ation et

 la maint

enance.

WARNIN

G/AVERT

ISSEMEN

T

!

Nocifs p

our la

 peau nue 

et les 

Veuillez 

lire et

 bien com

prendre 

l’instal

lation et

 la maint

enance.

Содержание UV100E series

Страница 1: ...ent Reduced power consumption and extended bulb life Communicates with other home appliances through Enviracom three wire communications bus Automatic brownout and high temperature protection for UV lamps Return air models supplied with integrated airflow sensor to monitor air flowing through ductwork Dual purpose reset button Commands lamp on with a single one second push Resets internal lamp run...

Страница 2: ...em is mounted in the supply side air duct or downstream or upstream from air conditioner evaporator coils in HVAC system It reduces mold growth and spores on duct surfaces coils and drip pans Does not use an airflow sensor Without Enviracom hooked up operates steady on off cycle lamp operates three hours on three hours off for a total two year life cycle With Enviracom hooked up after initial thre...

Страница 3: ...aviolet light to be seen after installation Do not attempt to bypass duct mount switch CAUTION Personal Injury Hazard Power supply can cause electrical shock Disconnect power supply before beginning installation Do not open base unit or lamp handle there are no user serviceable components inside Selecting Mounting Location CAUTION Equipment Damage Hazard Ultraviolet light can cause color shift or ...

Страница 4: ... Mount to allow correct operation a Do not mount upside down b Do not mount with lamps facing up CAUTION Sharp Edges Hazard Can cause personal injury Be careful when inserting ultraviolet device into sheet metal cutout Wear protective gloves when working near sheet metal Duct Mounting Use the following instructions to mount the UV System on the air duct of an HVAC system 1 Disconnect power to the ...

Страница 5: ...25 7 178 3 1 2 89 4 102 14 7 8 379 M20190A SURFACE TREATMENT SYSTEM 2 1 4 57 3 1 2 89 4 1 2 114 7 178 1 25 7 178 3 1 2 89 4 102 7 7 16 188 AIR TREATMENT SYSTEM SINGLE LAMP 1 2 12 M20191A 3 1 2 89 5 127 7 178 10 254 2 3 16 56 8 1 2 216 3 1 4 83 4 102 14 7 8 379 1 2 12 M20192A 3 1 2 89 5 127 AIR TREATMENT SYSTEM DUAL LAMP ...

Страница 6: ...clockwise This should cause the lamp handle to drop into the bottom of the lamp well 13 Rotate the lamp handle clockwise until it snaps into place with the lamp light indicator aligned with the raised button on the unit cover See Fig 6 Fig 6 Snap lamp handle into place WARNING UV Light Hazard Harmful to bare skin and eyes Can cause temporary or permanent loss of vision View illumination only throu...

Страница 7: ... follows a Bulb life means emitting adequate amount of UV C energy to maintain an effective kill rate At 0 bulb life remaining the lamp continues to operate until catastrophic bulb failure bulb burns out but the kill rate becomes rapidly negligible Installer should also orient the homeowner to the reset button on the bottom of the UV system that when pressed briefly for one second can be used to c...

Страница 8: ... longer only when replacing the bulb MAINTENANCE How You Can Maintain Your UV System You should regularly clean your ultraviolet lamp to maintain peak effectiveness of your air treatment or surface treatment system Replace the ultraviolet bulb when the LED status light on the front of your UV System is on steadily CAUTION Personal Injury Hazard Power supply can cause electrical shock Disconnect po...

Страница 9: ...tinue pushing and gently rotating counterclockwise until the lamp handle inserts fully into the base See Fig 14 Fig 14 Position lamp handle for insertion back into lamp base 8 Rotate the lamp handle clockwise until it snaps into place with the lamp light indicator aligned with the raised but ton on the unit cover See Fig 15 Fig 15 Snap lamp handle into place WARNING UV Light Hazard Harmful to bare...

Страница 10: ... SnapLamp handle 7 Insert the lamp handle into the base with the lamp light indicator at the eleven o clock position Continue pushing and gently rotating counterclockwise until the lamp handle inserts fully into the base See Fig 4 8 Rotate the lamp clockwise until it snaps into place with the lamp light indicator aligned with the raised button on the unit cover See Fig 6 9 Reconnect power to your ...

Страница 11: ... Handle Assembly Replacement Bulb UV100E1043 Air Treatment System single lamp left photo UC100E1006 UC18W1004 UV100E3007 Surface Treatment System center photo UC100E1030 UC36W1006 UV100E2009 Air Treatment System dual lamp right photo UC100E1030 two required UC36W1006 two required M18621B ...

Страница 12: ...on next page Fig 19 Air Treatment System dual lamp template M20194A CENTER OF 2 IN 51 MM HOLE FOR LAMP 1 1 2 IN 38 HOLE FOR AIRFLOW SENSOR CENTER OF AIRFLOW SENSOR HOLE 3 32 IN 3 MM PILOT HOLES FOR MOUNTING SCREWS ALIGN EITHER OF THESE LINES AS CLOSE AS POSSIBLE TO DUCT CENTER LINE INSTALLATION TEMPLATE FOR AIR TREATMENT SYSTEM SINGLE LAMP ...

Страница 13: ...MP 3 32 IN 3 MM PILOT HOLES FOR MOUNTING SCREWS ALIGN EITHER OF THESE LINES AS CLOSE AS POSSIBLE TO DUCT CENTER LINE INSTALLATION TEMPLATE FOR AIR TREATMENT SYSTEM DUAL LAMP 3 32 IN 3 MM PILOT HOLES FOR MOUNTING SCREWS CENTER OF AIRFLOW SENSOR HOLE 1 1 2 IN 38 HOLE FOR AIRFLOW SENSOR ...

Страница 14: ... 20 Surface Treatment System template M20193A CENTER OF 2 IN 51 MM HOLE FOR LAMP 3 32 IN 3 MM PILOT HOLES FOR MOUNTING SCREWS ALIGN EITHER OF THESE LINES AS CLOSE AS POSSIBLE TO DUCT CENTER LINE INSTALLATION TEMPLATE FOR SURFACE TREATMENT SYSTEM ...

Страница 15: ...UV100E ULTRAVIOLET SYSTEMS 15 68 0262 5 ...

Страница 16: ...nc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Toronto Ontario M1V 4Z9 customer honeywell com UV100E ULTRAVIOLET SYSTEMS U S Registered Trademark 2007 Honeywell International Inc 68 0262 5 M S Rev 03 07 ...

Отзывы: