9
68-0160
VR8345M
INSTALLATION
WIRING
CAUTION
Disconnect power supply before making wiring
connections to prevent electrical shock or equip-
ment damage.
Follow the wiring instructions furnished by the appli-
ance manufacturer, if available, or use the following gen-
eral instructions. Where these instructions differ from the
appliance manufacturer, follow the appliance manufacturer
instructions.
Fig. 8—Install wire adapter for hot surface or direct spark ignition systems. Pilot plug must be in the valve
pilot opening.
M8440
PV
MV
PV
MV
OFF
ON
PILOT GAS SEAL
(PLUG)
WIRE
ADAPTER
All wiring, including insulated quick connect terminals,
must comply with applicable electrical codes and ordinances.
1. Check the power supply rating on the gas control and
make sure it matches the available supply. Install thermostat
and other controls as required.
2. When the gas control is installed on a hot surface or
direct spark ignition system, attach the wire adapter provided
to the wiring terminals. See Fig. 8 for the wire terminal
location.
3. Connect control circuit to gas control terminals. See
Figs. 4 and 9 through 11.
4. Adjust the thermostat heat anticipator to 0.7, the rating
stamped on the valve operator.