Sensepoint XCD Technical Manual SPXCDHMANEN Issue 2
22
8.2 System Status
Display indications, current output and relay states for various operational conditions
are shown in the following table. For further details of error messages and trouble shooting
see section 12.3.
System Status
Status
Display
Current Output
Relay
Back
Light
A1
A2
Fault
Fault:
Circuit or sensor
error
F-XX
fault number
with fault icon
blinking
0-1.0 mA
Yellow,
flashing
System Fault
N/A
0-0.15mA
Note: In the event of processor failure the watchdog will automatically reset the system for
recovery.
Warning
W-XX
warning number
with fault icon
blinking
Dependent on
system status
Green
Steady
Normal
0.0
Gas
concentration
4-20 mA
Green
Steady
Alarm 1
Gas
concentration.
1
st
alarm icon
blinking
4-20 mA
Red,
flashing
Alarm 2
Gas
concentration.
2
nd
alarm icon
blinking
4-20 mA
1
Red,
flashing
Over-range
Full scale icon
and reading
blinking
22mA
2
Red,
flashing
Inhibit
Inhibit icon
dependent
on Menu
command. If
any relay is set
to inhibit relay,
then inhibit relay
will be activated.
2 or 4mA
depending on
configuration.
Note:
2 or 17.4mA for
Oxygen version
Green
Steady
Table 4: System status
Note:
1. For Oxygen, A1 relay will not be activated because AL1 is configured to activate above
23.5 %Vol (in Rising Alarm configuration).
2. For Oxygen, A2 relay will not be activated because AL2 is configured to activate below
19.5 %Vol (in Falling Alarm configuration).
Содержание Sensepoint XCD
Страница 1: ...Technical Manual Sensepoint XCD Gas Detector P R E L A U N C H ...
Страница 54: ...Sensepoint XCD Technical Manual SPXCDHMANEN Issue 2 54 17 6 Mounting Bracket Drawing ...
Страница 56: ...Sensepoint XCD Technical Manual SPXCDHMANEN Issue 2 56 China GB Ex English Version ...
Страница 57: ...Sensepoint XCD Technical Manual SPXCDHMANEN Issue 2 57 China PA Certification ...
Страница 58: ...Sensepoint XCD Technical Manual SPXCDHMANEN Issue 2 58 18 2 Korea KTL ...
Страница 59: ...Sensepoint XCD Technical Manual SPXCDHMANEN Issue 2 59 18 3 European ATEX ATEX For Transmitter ...
Страница 60: ...Sensepoint XCD Technical Manual SPXCDHMANEN Issue 2 60 ATEX for Sensor ...
Страница 61: ...Sensepoint XCD Technical Manual SPXCDHMANEN Issue 2 61 18 4 International IEC IEC Ex for Transmitter ...
Страница 62: ...Sensepoint XCD Technical Manual SPXCDHMANEN Issue 2 62 IEC Ex for Sensor ...