background image

Sensing and Internet of Things    

7

Sensor Evaluation Kit, SEK002

Issue A

32333651

Table 5. Measurement Screen Functions for ABP Series Only

Function

Description

Input Panel:

   Temperature
   Pressure
   #Samples to Avg.
   Auto Range

Selects the desired graph parameters. Click on the “Play” 
button after making a selection to restart the evaluation.
Displays °C or °F of the sensor’s ASIC.
Displays the sensor’s pressure.
Select from the given number.
Select to automatically adjust to keep trace on screen.

Play/Pause

Starts/pauses the LIVE STREAMING function. Also used 
to restart an evaluation after changing any Input Panel 
characteristics.

Record

Records the measurements in a .cvs file in Excel for 
offline analysis.

Restart

Resets the time line to 0 sec.

Snap Shot

Saves a screenshot to a selected folder.

Saved Snaps Path 

Opens the folder of recent file clips and snap shots.

Captured File 
Clips

Displays/provides access to recent .cvs files in Excel. 

Part

Displays the part number of the sensor currently being 
evaluated.

Serial

Not displayed.

4.2 Measurement Screen (see Figures 6, 7 and Table 5)

Figure 6. Measurement Screen for ABP Series Only

Figure 7. Captured File Clip Sample for ABP 

Series Only

Note: The example given shows the display for a pressure sensor (ABP Series, MPR series). The HumidIcon products display is similar 
and returns the %RH (percent relative humidity) and temperature. The HPM Series Particle Sensor returns the PM2.5 in red and the 
PM10 in blue, both expressing concentration in 

μ

g/m

3

.

Содержание SEK002

Страница 1: ... displayed on the PC s screen The readings may also be recorded to a csv file for further analysis Sensors may be mounted directly on the SEK002 or remotely connected to the SEK002 via wire leads allowing the sensor to be tested in adverse environments or in a prototype product for proof of concept testing 2 0 SEK002 AND USER PROVIDED COMPONENTS 2 1 Assemble the components shown in Table 1 Table 1...

Страница 2: ...kages I2 C output Particle Sensors HPM Series UART output SMT DIP 2 2 Choose the sensor to be evaluated Click on the links to the specific series in Table 2 to access the product datasheets SIP SOIC 8 Leadless SMT Leadless SMT mounted on breakout board Leadless SMT unmounted Note A specialized cable 32332297 001 shown below and available separately from Honeywell is required for use with the HPM S...

Страница 3: ...le 3 2 3 Connect the sensor to be evaluated to the SEK002 The SEK002 is preconfigured with jumpers in order to evaluate an ABP Series sensor I2 C 5 Vdc For the purposes of these User Instructions the part number being evaluated is ABPDLNN100MG2A5 Note For the other compatible sensors see Appendix C for the jumper selections and configure the jumpers accordingly Mount the ABPDLNN100MG2A5 in the app...

Страница 4: ...g the software 3 Click on Sensor Evaluation Kit SEK002 Version 1 0 exe downloaded in Step 1 a and run the software Follow the InstallShield Wizard to complete the installation If prompted for device drivers install the VCP drivers also located in Sensor Evaluation Kit Version 1 0 exe This step is required only when the SEK002 is connected to a USB port for the first time Go to your computer s Devi...

Страница 5: ...Step 1 a a Find the device in Device Manager and right click on it b Select Update driver software c Choose Browse my computer for driver software and provide the path to the VCP driver contained in the software download in Step 1 a The default path is C Program Files x86 Honeywell SensorEvaluationKit VirtualCOM This will change the VCP driver to version 1 2 2 0 which you can then verify in the dr...

Страница 6: ...st several digits appear Then select the final part number from the remaining drop down list After the part number appears click on the SUBMIT button Note Do not enter the entire Part Number or copy paste it into the field The Part Number must be selected from the drop down list Serial Number Not used RECENT SELECTIONS If applicable a part number may be selected from this list directly It is not n...

Страница 7: ...measurements in a cvs file in Excel for offline analysis Restart Resets the time line to 0 sec Snap Shot Saves a screenshot to a selected folder Saved Snaps Path Opens the folder of recent file clips and snap shots Captured File Clips Displays provides access to recent cvs files in Excel Part Displays the part number of the sensor currently being evaluated Serial Not displayed 4 2 Measurement Scre...

Страница 8: ... or F of the sensor s ASIC File Type Default is a csv file which displays in Excel File Name Default is LOGDATA Change by entering a different FIle Name File Path Default is C ProgramData SensorEvalKit Report Note Drive location depends on the Windows installation location Change by entering a different File Path or use BROWSE File Size Limit Default is1024kB may beadjustedforasinglefile 4 3 Confi...

Страница 9: ...s Software Provides software revision number and release date Getting Started Provides links to User Instructions and online sensor product information including datasheets installation instructions and applications notes Contact Support Requests technical support from Honeywell 4 4 Help Screen see Figure 9 and Table 7 Figure 9 Help Screen ...

Страница 10: ...ersion 1 0 hex XLoader zip 1 See Appendix B Remote Connection if evaluation conditions are different Table B1 ABP Series Pinout SEK002 Sensor Socket Designator Pin Pin Pad Designator I2 C Pin Pad SPI Pin Pad Function J5 3 MISO 5 sensor output J4 3 SCLK 6 clock P3 51 SS 3 chip select for DIP P3 61 SS 3 chip select for SMT P3 71 SS 3 chip select for leadless SMT P5 5 V or 3 3 V Vsupply 2 2 supply P5...

Страница 11: ...ix E for more information on using the MPR Series breakout boards Table B3 HumidIcon HIH6000 Series HIH6100 Series HIH7000 Series HIH8000 Series HIH9000 Series Pinout SEK002 Sensor Socket Designator Pin Pin I2 C Pin SPI Pin SOIC Function SIP SOIC P2 5 MISO 5 sensor output P2 6 SCLK 4 clock P2 1 CS 3 chip select P5 5 V or 3 3 V VCC 1 8 8 supply P5 6 GND 2 2 2 ground J14 2 SDA 4 4 SDA J13 2 SCL 3 3 ...

Страница 12: ...ing some ratiometricity error To use an external power remove the jumper from J6 and supply the external power to pin 3 COM on J6 Note Make these connections prior to powering the Arduino Uno Rev3 through the USB cable in Table 3 Step 2 Ensure that the SEK002 terminals are not damaged when connecting the external power supply Table C2 MPR Series Common Power Supply Selection Output Leadless SMT Pa...

Страница 13: ...Sensing and Internet of Things 13 Sensor Evaluation Kit SEK002 Issue A 32333651 APPENDIX D SEK002 EXTERNAL FEATURES AND DIMENSIONS Figure D1 SEK002 Board Layout Front no jumpers shown Back ...

Страница 14: ...nd Internet of Things Sensor Evaluation Kit SEK002 Issue A 32333651 APPENDIX D SEK002 EXTERNAL FEATURES AND DIMENSIONS continued Figure D1 SEK002 Dimensions For reference only mm in 72 53 2 87 53 3 2 10 23 24 0 91 ...

Страница 15: ...ensor without the risk of hand soldering or the expense of creating your own evaluation PCB The breakout board can be used with the SEK002 Sensor Evaluation Kit and software or any I2 C or SPI control circuit If the SEK002 is not used please provide 1 kOhm pull up resistors on SCL and SDA lines when using I2 C communications Refer to the MPR Series data sheet for programming instructions Dimension...

Страница 16: ...terature and the Honeywell web site it is buyer s sole responsibility to determine the suitability of the product in the application Specifications may change without notice The information we supply is believed to be accurate and reliable as of this writing However Honeywell assumes no responsibility for its use Honeywell serves its customers through a worldwide network of sales offices and distr...

Отзывы: