manualshive.com logo in svg
background image

RA889A SWITCHING RELAY

68-0216—2

2

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the 
TRADELINE® Catalog or price sheets for complete ordering number.

If you have additional questions, need further information, or would like to comment on our products or services, please write or 
phone:

1.

Your local Home and Building Control Sales Office (check white pages of your phone directory).

2.

Home and Building Control Customer Logistics
Honeywell Inc., 1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386 (612) 951-1000

In Canada—Honeywell Limited/Honeywell Limitée, 155 Gordon Baker Road, North York, Ontario M2H 3N7.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, 
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.

SPECIFICATIONS

IMPORTANT

The specifications given in this publication do not 
include normal manufacturing tolerances. Therefore, 
this unit may not exactly match the listed specifica-
tions. Also, this product is tested and calibrated 
under closely controlled conditions, and some minor 
differences in performance can be expected if those 
conditions are changed.

TRADELINE® Model: RA889A Switching Relay with 24V 
controller for switching one-line voltage load.

Electrical Ratings:
Voltage: 120 Vac, 60 Hz.
Thermostat Heat Anticipator Setting: 0.12A.

Transformer Ratings:
Primary: 120 Vac, 60 Hz.
Secondary: 24 Vac, 12 VA maximum, 9 VA available for exter-

nal loads. Secondary protected by replaceable 1A automo-
tive fuse.

Contact Ratings: 15 AFL, 30 ALR; maximum connected load 
2000 VA.

Temperature Ratings: Ambient: -20°F to 120°F (-29°C to 
49°C).

Humidity Ratings: 0 to 90% rh, non-condensing.

Switching Action: Spdt, plus Powerpile® rated low voltage 
Spst relay.

Electrical Connections: No. 8 captivated wire clamp screw 
terminals.

Finish: Zinc plated steel.

Knockouts:
Case Bottom: Three 1/2 in. (13 mm) for conduit box.
Case Top: One 7/8 in. (22 mm) for wiring.

Approvals:
Underwriters Laboratories Inc. Listed: File no. E4436, Guide 

no. XAPX.

Canadian Underwriters Laboratories Inc. Listed: Guide no. 

XAPX7.

Dimensions: See Fig. 1.

Fig. 1. RA889A dimensions in in. (mm).

7/32 (6) 
DIAMETER 
MOUNTING 
HOLE

KNOCKOUT 
FOR 1/2 (13) 
CONDUIT (3)

1-1/16

(27)

1-1/4 (32)

2-3/16

(56)

3-1/2

(89)

3-11/16 (94)

5/16

(8)

5/16 (8)

6-1/4
(159)

5-3/8
(137)

1-3/8 (35)

4-7/16 (118)

2-1/8

(54)

3/16 (5) DIAMETER

3/8 (10) DIAMETER

7/8(22) 
DIAMETER

KEYHOLE 
TYPE
MOUNTING 
HOLE

M17512

Содержание RA889A

Страница 1: ...ystems FEATURES High load switching capability Troubleshooting LED Push to test button Replaceable transformer fuse Long life DC relay drive control technology Relay for use with external 24 Vac or 24 Vdc supply with line voltage control or with internal 24V transformer supply One model replaces many Honeywell models See Table 1 Replacement Cross Reference Contents Application 1 Features 1 Specifi...

Страница 2: ... closely controlled conditions and some minor differences in performance can be expected if those conditions are changed TRADELINE Model RA889A Switching Relay with 24V controller for switching one line voltage load Electrical Ratings Voltage 120 Vac 60 Hz Thermostat Heat Anticipator Setting 0 12A Transformer Ratings Primary 120 Vac 60 Hz Secondary 24 Vac 12 VA maximum 9 VA available for exter nal...

Страница 3: ... supply before wiring MOUNTING In replacement applications mount the new relay in the same location as the old relay For new installations locate the relay vertically on a solid wall or partition as close as possible to the device to be controlled Select a location that is easily accessible for installation and service NOTE To reduce the possible transformer hum and relay noise that is sometimes a...

Страница 4: ...used to provide electrical isolation in low voltage circuits if powered from a 24 Vac or 24 Vdc external source connected to W T and C Fiber barriers separate line and low voltage connections CHECKOUT 1 Keep the cover on the relay during normal operation and remove only for service and checkout 2 Relay contacts require no cleaning they are arranged to close with a wiping action and are self cleani...

Страница 5: ...ASE MUST BE CONNECTED TO EARTH GROUND USE GROUNDING SCREW PROVIDED B1 IS 1 4 IN TAB TERMINAL 1 2 L7148A L8148A 2 1 M14301 3 3 X2 X1 N O COM L2 L1 W T R T X2 X1 N O COM L2 L1 W T R T X2 X1 N O COM L2 L1 W T R T R T W T R T W T R T W T L1 L2 COM N O X1 X2 G L2 L1 T T C1 C2 B2 B1 L1 HOT L2 PUMP PUMP PUMP T87F T87F T87F RA889A RELAY RA889A RA889A POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROT...

Страница 6: ...CONNECTED TO EARTH GROUND USE GROUNDING SCREW PROVIDED 1 1 20 VA M13321 R8888 1 G RA889A R T W T TO APPROPRIATE CONNECTIONS AS REQUIRED BY THE SYSTEM H1 H2 TYPICALLY CONNECTED TO T T OF BURNER CONTROL SYSTEM ZC H1 H2 2 2 USE COPPER CONDUCTORS ONLY FOR ALL CLASS 1 CONNECTIONS USE WIRE RATED FOR AT LEAST 167 F 75 C G L2 L1 3 4 4 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIR...

Страница 7: ...ED OUTPUTS X2 X1 LOW VOLTAGE CONTROLLED OUTPUT L1 L2 COM N C N O C RA889A JUMPER LINE VOLTAGE CONTROL NEUTRAL X2 X1 L1 L2 COM N C N O C RA889A NEUTRAL X2 X1 24V CONTROLLER INPUT SUPPLY R T W T R T W T 1 REQUIRED FOR OUTPUT LED OPERATION 2 FOR SERIES 10 OR OTHER HARDWIRED ELECTRONIC 3 WIRE THERMOSTATS 3 WARNING ELECTROCUTION HAZARD POWER SUPPLY CAN CAUSE SEVERE INJURY OR DEATH DISCONNECT POWER BEFO...

Страница 8: ...well Plaza 155 Gordon Baker Road Sun Hung Kai Centre P O Box 524 North York Ontario No 30 Harbour Road Minneapolis MN 55408 0524 M2H 3N7 Wanchai Hong Kong Honeywell Latin American Region Honeywell Europe S A 480 Sawgrass Corporate Parkway 3 Avenue du Bourget Suite 200 1140 Brussels Sunrise FL 33325 Belgium Printed in U S A on recycled paper containing at least 10 post consumer paper fibers ...

Отзывы: