SPECIFICATIONS
S
YSTEM
C
APACITY
•
Intelligent Signaling Line Circuits .......................................1
•
Intelligent detectors .......................................................159
•
Addressable monitor/control modules ............................159
•
Programmable internal hardware and output circuits ........4
•
Programmable software zones .........................................99
•
Special programming zones .............................................14
•
LCD annunciators per CPU-320SYS/E
(observe power)
..................................................................... 32
•
ACS annunciators
per CPU-320SYS/E............................ 32 addresses x 64 points
P
OWER
S
PECIFICATIONS
•
Primary input power:
–
CPU-320SYS board: 120 VAC, 50/60 Hz, 5.0 A.
–
CPU-320SYS/E board: 220/240 VAC, 50/60 Hz, 2.5 A.
•
Current draw (standby/alarm):
–
CPU-320SYS
(E) board: 0.250 A. Add 0.035 A for each NAC in
use.
–
KDM-R2 (Backlight on): 0.100 A.
•
Total output 24 V power: 6.0 A in alarm.
NOTE:
The power supply has a total of 6.0 A of available power. This is
shared by all internal circuits. See Installation Manual for a complete cur-
rent draw calculation sheet.
•
Standard notification circuits (4): 1.5 A each.
•
Resettable regulated 24V power: 1.25 A.
•
Two non-resettable regulated 24V power outputs:
–
1.25 A.
–
0.50 A.
•
Non-resettable 5V power: 0.15 A.
•
Battery charger range: 18 AH – 200 AH. Use separate cabinet for
batteries over 26 AH.
•
Float rate: 27.6 V.
P
HYSICAL
S
PECIFICATIONS
•
Cabinet:
NFS-320SYS systems can be installed in CAB-4 Series
cabinets
(three sizes with various door options, see DN-6857)
.
•
Shipping Weight:
–
CPU-320SYS: 16.95 lb (7.69 kg).
–
CPU-320SYSE: 17.2 lb (7.80 kg).
T
EMPERATURE
AND
H
UMIDITY
R
ANGES
This system meets NFPA requirements for operation at 0 – 49°C/32
– 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at
32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's
standby batteries and the electronic components may be adversely
affected by extreme temperature ranges and humidity. Therefore, it
is recommended that this system and its peripherals be installed in
an environment with a normal room temperature of 15 – 27°C/60 –
80°F.
A
GENCY
L
ISTINGS
AND
A
PPROVALS
The listings and approvals below apply to the basic NFS-32SYS
control panel. In some cases, certain modules may not be listed by
certain approval agencies, or listing may be in process. Consult fac-
tory for latest listing status.
•
UL Listed
: S635.
•
ULC Listed:
S527-11.
•
FM Approved.
•
CSFM:
7165-0028:0243.
•
Fire Dept. of New York:
COA #6212.
NOTE:
For additional information on UL-listed model NFS-320 see DN-
7112. For additional information on UL- and ULC-listed model NFS-
320C, see DN-60085.
Marine Applications:
Marine approved systems must be config-
ured using components itemized in this document. (See Main Sys-
tem Components, in “Product Line Information.) Specific
connections and requirements for those components are described
in the installation document, PN 54756. When these requirements
are followed, systems are approved by the following agencies:
•
US Coast Guard
161.002/50/0, 161.002/55/0 (Standard 46 CFR
and 161.002).
•
Lloyd's Register
11/600013 (ENV 3 category).
•
American Bureau of Shipping
(ABS) Type Approval.
NOTE:
For information on marine applications, see DN-60688.
S
TANDARDS
The NFS-320SYS complies with the following UL Standards and
NFPA 72, International Building Code (IBC), and California Building
Code (CBC) Fire Alarm Systems requirements:
•
UL 864
, 10th edition (Control Units and Accessories for Fire
Alarm Systems).
•
UL 2610
(Commercial Premises Security Alarm Units and
Systems).
•
UL 2572
(Mass Notification Systems). (NFS-320SYS version 20
or higher).
•
ULC-S527-11
Standard for the Installation of Fire Alarm Sys-
tems.
•
LOCAL
(Automatic, Manual, Waterflow and Sprinkler Supervi-
sory).
•
AUXILIARY
(Automatic, Manual and Waterflow) (requires TM-4).
•
REMOTE STATION
(Automatic, Manual, Waterflow and Sprinkler
Supervisory) (requires TM-4).
•
PROPRIETARY
(Automatic, Manual, Waterflow and Sprinkler
Supervisory).
Not applicable for FM.
•
CENTRAL STATION
(Automatic, Manual, Waterflow and Sprin-
kler Supervisory) (requires DACT).
•
EMERGENCY VOICE/ALARM
.
•
OT, PSDN
(Other Technologies, Packet-switched Data Network).
•
IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000
(Seismic).
•
CBC 2007
(Seismic).