Honeywell Notifier NFS-320SYS Скачать руководство пользователя страница 7

NOTI•FIRE•NET™, ONYXWorks™, and SWIFT™ are all trademarks of and FlashScan®,

NOTIFIER®, ONYX®, VeriFire® Tools, and VIEW® are all registered trademarks of Hon-

eywell International Inc. 

©2022 by Honeywell International Inc. All rights reserved. Unauthorized use of this docu-

ment is strictly prohibited.

This document is not intended to be used for installation purposes.

We try to keep our product information up-to-date and accurate. 

We cannot cover all specific applications or anticipate all requirements.

All specifications are subject to change without notice.

Country of Origin: USA

NOTIFIER

12 Clintonville Road 

Northford, CT 06472 

203.484.7161 

www.notifier.com

SPECIFICATIONS

S

YSTEM

 C

APACITY

Intelligent Signaling Line Circuits .......................................1

Intelligent detectors  .......................................................159

Addressable monitor/control modules ............................159 

Programmable internal hardware and output circuits  ........4

Programmable software zones .........................................99

Special programming zones .............................................14

LCD annunciators per CPU-320SYS/E

(observe power)

..................................................................... 32

ACS annunciators
per CPU-320SYS/E............................ 32 addresses x 64 points

P

OWER

 S

PECIFICATIONS

Primary input power:

CPU-320SYS board: 120 VAC, 50/60 Hz, 5.0 A. 

CPU-320SYS/E board: 220/240 VAC, 50/60 Hz, 2.5 A.

Current draw (standby/alarm):

CPU-320SYS

(E) board: 0.250 A. Add 0.035 A for each NAC in

use. 

KDM-R2 (Backlight on): 0.100 A.

Total output 24 V power: 6.0 A in alarm.

NOTE: 

The power supply has a total of 6.0 A of available power. This is

shared by all internal circuits. See Installation Manual for a complete cur-
rent draw calculation sheet.

Standard notification circuits (4): 1.5 A each.

Resettable regulated 24V power: 1.25 A.

Two non-resettable regulated 24V power outputs: 

1.25 A. 

0.50 A.

Non-resettable 5V power: 0.15 A.

Battery charger range: 18 AH – 200 AH. Use separate cabinet for
batteries over 26 AH.

Float rate: 27.6 V.

P

HYSICAL

 S

PECIFICATIONS

Cabinet: 

NFS-320SYS systems can be installed in CAB-4 Series

cabinets 

(three sizes with various door options, see DN-6857)

.

Shipping Weight: 

CPU-320SYS: 16.95 lb (7.69 kg).

CPU-320SYSE: 17.2 lb (7.80 kg).

T

EMPERATURE

 

AND

 H

UMIDITY

 R

ANGES

This system meets NFPA requirements for operation at 0 – 49°C/32
– 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at
32°C ± 2°C (90°F ± 3°F).  However, the useful life of the system's
standby batteries and the electronic components may be adversely
affected by extreme temperature ranges and humidity. Therefore, it
is recommended that this system and its peripherals be installed in
an environment with a normal room temperature of 15 – 27°C/60 –
80°F. 

A

GENCY

 L

ISTINGS

 

AND

 A

PPROVALS

The listings and approvals below apply to the basic NFS-32SYS
control panel. In some cases, certain modules may not be listed by
certain approval agencies, or listing may be in process. Consult fac-
tory for latest listing status. 

UL Listed

: S635.

ULC Listed: 

S527-11.

FM Approved.

CSFM: 

7165-0028:0243. 

Fire Dept. of New York:

 COA #6212.

NOTE: 

For additional information on UL-listed model NFS-320 see DN-

7112. For additional information on UL- and ULC-listed model NFS-
320C, see DN-60085. 

Marine Applications:

 Marine approved systems must be config-

ured using components itemized in this document. (See Main Sys-
tem Components, in “Product Line Information.) Specific
connections and requirements for those components are described
in the installation document, PN 54756. When these requirements
are followed, systems are approved by the following agencies:

US Coast Guard 

161.002/50/0, 161.002/55/0 (Standard 46 CFR

and 161.002).

Lloyd's Register

 11/600013 (ENV 3 category).

American Bureau of Shipping

 (ABS) Type Approval. 

NOTE: 

For information on marine applications, see DN-60688. 

S

TANDARDS

The NFS-320SYS complies with the following UL Standards and
NFPA 72, International Building Code (IBC), and California Building
Code (CBC) Fire Alarm Systems requirements:

UL 864

, 10th edition (Control Units and Accessories for Fire

Alarm Systems).

UL 2610

 (Commercial Premises Security Alarm Units and

Systems).

UL 2572

 (Mass Notification Systems). (NFS-320SYS version 20

or higher).

ULC-S527-11

 Standard for the Installation of Fire Alarm Sys-

tems.

LOCAL

 (Automatic, Manual, Waterflow and Sprinkler Supervi-

sory).

AUXILIARY

 (Automatic, Manual and Waterflow) (requires TM-4).

REMOTE STATION

 (Automatic, Manual, Waterflow and Sprinkler

Supervisory) (requires TM-4).

PROPRIETARY

 (Automatic, Manual, Waterflow and Sprinkler

Supervisory). 

Not applicable for FM.

CENTRAL STATION

 (Automatic, Manual, Waterflow and Sprin-

kler Supervisory) (requires DACT).

EMERGENCY VOICE/ALARM

.

OT, PSDN

 (Other Technologies, Packet-switched Data Network).

IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000

 (Seismic).

CBC 2007

 (Seismic).

Содержание Notifier NFS-320SYS

Страница 1: ...detectors notification or relay wireless modules are available for use with the FWSG A Standard 80 character display Network options High speed network for up to 200 nodes N16e x NFS2 3030 NFS2 640 NFS 320 C NFS 320SYS NCD NCA 2 DVC EM ONYXWorks NFS 3030 NFS 640 and NCA Standard network for up to 103 nodes N16e x NFS2 3030 NFS2 640 NFS 320 C NFS 320SYS NCD NCA 2 DVC EM ONYXWorks NCS NFS 3030 NFS 6...

Страница 2: ...overlapping net work coverage RELEASING FEATURES Ten independent hazards Sophisticated cross zone three options Delay timer and Discharge timers adjustable Abort four options Low pressure CO2 listed VOICE FEATURES Integrates with FirstCommand Series See DN 60772 Telephone applications require NFC FFT HIGH EFFICIENCY OFFLINE SWITCHING 3 0 A POWER SUPPLY 6 0 A IN ALARM 120 VAC NFS 320 NFS 320C 240 V...

Страница 3: ...ls 1 Low Chamber value 2 Maintenance Alert indicative of dust accumulation that is near but below the allowed limit 3 Maintenance Urgent indicative of dust accumulation above the allowed limit Sensitivity Adjust Nine sensitivity levels are provided for alarm detection These levels can be set manually or can change automat ically between day and night Nine levels of pre alarm sensitivity can also b...

Страница 4: ...h speed Network Commu nications Modules Wire single mode fiber multi mode fiber and media conversion models are available See DN 60454 NCD As part of a standalone NFS 320SYS system the NCD can serve as Primary Display for the panel to provide control and status capabilities on displayless nodes On network systems the NCD connects to and requires a standard Network Communication Mod ule or High Spe...

Страница 5: ...gent 135 F fixed thermal sensor FlashScan and CLIP Must be mounted to one of the bases listed below ULC FST 951A IV FST 951R White low profile intelligent rate of rise thermal sensor FlashScan only Must be mounted to one of the bases listed below ULC FST 951A FSP 951R IV Ivory low profile intelligent photoelectric sensor remote test capable FlashScan only ULC FSP 95RA IV for use with DNRA FSV 951 ...

Страница 6: ... MB for systems using 100 AH batteries For a full list of required and optional equipment see DN 60688 NFS LBB Battery Box required for batteries larger than 26 AH NFS LBBR Same as above but red SEISKIT 320 B26 Seismic mounting kit Required for seismic certi fied applications with NFS 320 and BB 26 Includes battery bracket for two 26 AH batteries SEISKIT BB25 Seismic mounting kit for the BB 25 Inc...

Страница 7: ... the useful life of the system s standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity Therefore it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 27 C 60 80 F AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to the basic NFS 32SYS control pane...

Отзывы: