Page 6 of 7 — DN-60637:N • 9/15/2022
B200S-IV:
Ivory intelligent, programmable sounder base. ULC:
B200SA-IV.
B200SCOA-WH:
White intelligent, programmable sounder base in
English/French (required in Canada for ULC applications with CO
detectors. Based on B200SA. ULC listed.
B200SCOA-IV:
Ivory intelligent, programmable sounder base in
English/French (required in Canada for ULC applications with CO
detectors. Based on B200SA. ULC listed.
B200S-LF-WH:
White, low-frequency version of B200S. See DN-
60054.
B200S-LF-IV:
Ivory, low-frequency version of B200S.
B200SR-WH:
White intelligent programmable sounder base, Tem-
poral 3 or Continuous tone. For retrofit installations replacing
B501BH series bases.
See DN-60054.
ULC: B200SRA-WH.
B200SR-IV:
Ivory intelligent programmable sounder base, Temporal
3 or Continuous tone. For retrofit installations replacing B501BH
series bases. ULC: B200SRA-IV.
B200SR-LF-WH
: White, low-frequency version of B200SR.
See DN-
60054.
B200SR-LF-IV:
Ivory, low-frequency version of B200SR.
FMM-1:
FlashScan monitor module.
See DN-6720.
FDM-1(A):
FlashScan dual monitor module.
See DN-6720.
FZM-1(A):
FlashScan two-wire detector monitor module.
See DN-
6720.
FMM-101(A):
FlashScan miniature monitor module.
See DN-6720.
FCM-1(A):
FlashScan control module.
See DN-6724.
FCM-1-REL(A):
FlashScan releasing control module.
See DN-
60390.
FRM-1(A):
FlashScan relay module.
See DN-6724.
FDRM-1(A):
FlashScan dual monitor/dual relay module.
See DN-
60709.
NBG-12LX:
Manual pull station, addressable.
See DN-6726.
N-MPS series:
Manual pull stations, addressable and conventional.
For use in Canada only.
See DN-5497 and DN-60629.
ISO-X(A):
Isolator module.
See DN-2243.
ISO-6(A)
: Six fault isolator module.
See DN-60844.
XP6-C(A):
FlashScan six-circuit supervised control module.
See
DN-6924.
XP6-MA(A):
FlashScan six-zone interface module; connects intelli-
gent alarm system to two-wire conventional detection zone.
See DN-
6925.
XP6-R(A):
FlashScan six-relay (Form-C) control module.
See DN-
6926.
XP10-M(A):
FlashScan ten-input monitor module.
See DN-6923.
E
NCLOSURES
, C
HASSIS
,
AND
D
RESS
P
LATES
CAB-4 Series Enclosure:
NFS-320SYS can mount in a standard
CAB-4 Series enclosure.
See DN-6857 for CAB-4 options.
CAB-5 Series Enclosure:
NFS-320SYS can mount in CAB-5
Series enclosures designed for INSPIRE panels, using CHS-ADP
adapter plate.
See DN-62113 for CAB-5 options.
CAB-BM Marine System:
Protects equipment in shipboard and
waterfront applications. Also order
BB-MB
for systems using
100 AH batteries. For a full list of required and optional equipment,
see
DN-60688.
NFS-LBB:
Battery Box (required for batteries larger than 26 AH).
NFS-LBBR:
Same as above, but red.
SEISKIT-320/B26:
Seismic mounting kit. Required for seismic-certi-
fied applications with NFS-320 and BB-26. Includes battery bracket
for two 26 AH batteries.
SEISKIT-BB25:
Seismic mounting kit for the BB-25. Includes battery
bracket for two 26 AH batteries.
SEISKIT-LBB:
Seismic kit for the NFS-LBB. Includes battery bracket
for two 55 AH batteries.
Backboxes
NOTE: “C” suffix indicates ULC-Listed modell:
ABF-1B
Annunciator Flush Box.
ABF-1DB(C)
Annunciator Flush Box with Door.
ABF-2B
Annunciator Flush Box
ABF-2DB(C)
Annunciator Flush Box with Door
ABF-4B
Annunciator Flush Box
ABS-1TB(C)
Annunciator Surface Box
ABS-1B(C)
Annunciator Surface Box
ABS-2B
Annunciator Surface Box
ABS-2D(C)
Annunciator Surface Box
ABS-4D(C)
Annunciator Surface Box
BB-UZC:
Backbox for housing the UZC-256. Required for NFS-320
applications. Black. For red, order BB-UZC-R.
O
THER
O
PTIONS
CGW-MB
: CLSS Gateway for Internet/cloud-based communication
between the FACP and peripheral devices.
See HON-62034.
HON-CGW-MBB
: CLSS Gateway, pre-installed in a cabinet.
See
HON-62034.
411:
Slave Digital Alarm Communicator.
See DN-6619.
411UDAC:
Digital Alarm Communicator.
See DN-6746.
IPDACT-2/2UD, IPDACT Internet Monitoring Module:
Connects to
primary and secondary DACT telephone output ports for internet
communications over customer-provided Ethernet connection.
Requires compatible Teldat VisorALARM Central Station Receiver.
Can use DHCP or static IP.
See DN-60408.
IPSPLT:
Y-adapter option allow connection of both panel dialer out-
puts to one IPDACT-2/2UD cable input.
IPENC:
External enclosure for IPDACT, includes IPBRKT mounting
bracket; Red. For Black order
IPENC-B
.
HWF2V-COM:
LTE Digital Cellular Fire Alarm Communicator and
Internet Panel, Verizon LTE / IP. Provides selectable configurable
paths: cellular only, IP only, or IP primary with cellular backup. Con-
nects to the primary and secondary ports of a DACT.
See DH-62010.
(
For Canadian applications order IPGSM-4GC.
See DH-60771
.)
HWF2A-COM:
LTE Digital Cellular Fire Alarm Communicator and
Internet Panel, AT&T LTE / IP. Provides selectable configurable
paths: cellular only, IP only, or IP primary with cellular backup. Con-
nects to the primary and secondary ports of a DACT.
(
For Canadian
applications order IPGSM-4GC.
See DH-60771
.)
NOTE:
For other options including compatibility with retrofit equipment,
refer to the panel's installation manual, the SLC manual, and the Device
Compatibility Document.