GS1 DataBar Expanded Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description
(page 6-2) for additional information. Mini-
mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
Trioptic Code
Trioptic Code is used for labeling magnetic storage media.
On
Trioptic
Redundancy
If you are encountering errors when reading Trioptic bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the
Tri-
opitc Redundancy
bar code below, then scan a redundancy count
between 0 and 10 on the
Programming Chart
inside the back cover of this
manual. Then scan the
Save
bar code.
Default = 0.
Tripotic Redundancy
6-64