Timeout Retries
This setting limits the number of Communication Timeout retries. If
the Timeout Retries is set to 0, the transmission is terminated after
the ini-tial Communication Timeout. Scan the bar code below, then
set the number of retries (from 0-255) by scanning digits from the
Programming Chart
, then scanning
Save
. (5 is the recommended set-
ting.)
Default = 0.
Timeout Retries
Communication Timeout Beeper
This selection programs the engine to issue an error beep when a
communication timeout has occurred. The error beep sound is pro-
grammed using
Number of Beeps – Error
(page 3-4).
Default = On.
Off
* On
NAK Retries
This selection limits the number of NAK retries that can occur in ACK/NAK
mode. Scan the bar code below, then set the number of retries (from 0-
255)
by scanning digits from the
Programming Chart
, then scanning
Save
. (5 is the recommended setting.)
Default = 0, or disabled.
NAK Retries
2-21
Содержание N431X
Страница 1: ...N431X Decoded Laser Scan Engine User s Guide ...
Страница 6: ......
Страница 14: ...x ...
Страница 20: ...1 6 ...
Страница 74: ...4 10 ...
Страница 160: ...6 68 ...
Страница 164: ...7 4 ...
Страница 168: ...8 4 ...
Страница 202: ...9 34 ...
Страница 216: ...A 10 ...
Страница 217: ......
Страница 219: ...Sample Symbols Matrix 2 of 5 6543210 GS1 DataBar 01 00123456789012 ...
Страница 220: ...Programming Chart 0 1 2 3 4 5 6 7 8 9 ...
Страница 222: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 N431X UG Rev B 12 12 ...