LYNX Touch Installation and Setup Guide
- 9 -
Wiring Connections
5000-100-094-V4
Make Earth Ground Connection
- The de
s
ign
a
ted e
a
rth gro
u
nd
termin
a
l EGND m
us
t
b
e termin
a
ted in
a
good e
a
rth gro
u
nd for the
lightning tr
a
n
s
ient protective device
s
in thi
s
prod
u
ct to
b
e effective.
The following
a
re ex
a
mple
s
of good e
a
rth gro
u
nd
s
a
v
a
il
ab
le
a
t
mo
s
t in
s
t
a
ll
a
tion
s
:
Met
a
l Cold W
a
ter Pipe -
S
ec
u
re
a
non-corro
s
ive met
a
l
s
tr
a
p
(copper i
s
recommended) to the pipe th
a
t i
s
electric
a
lly connected
a
nd
s
ec
u
red to which the gro
u
nd le
a
d i
s
electric
a
lly connected
a
nd
s
ec
u
red.
AC Power O
u
tlet Gro
u
nd - Av
a
il
ab
le from
3
-prong, 120VAC power
o
u
tlet
s
only. To te
s
t the integrity of the gro
u
nd termin
a
l,
us
e
a
three-wire circ
u
it te
s
ter with neon l
a
mp indic
a
tor
s
,
su
ch
as
the UL
Li
s
ted Ide
a
l Model 61-0
3
5, or e
qu
iv
a
lent,
a
v
a
il
ab
le
a
t mo
s
t
electric
a
l
su
pply
s
tore
s
.
Make Phone Line Connections
- For loc
a
l or f
u
ll line
s
eiz
u
re
follow the
a
ppropri
a
te
s
tep
s
b
elow.
Local Seizure
1.
2.
3
.
4.
c.
d.
e.
f.
a
.
b
.
c.
a
.
b
.
a
.
Connect the incoming phone line to the termin
a
l
s
TIP
a
nd RING
on the Control
as
s
hown on the
Su
mm
a
ry of Connection
s
.
Connect the h
a
nd
s
et phone line
s
to termin
a
l
s
H/
S
T (TIP)
a
nd
H/
S
R (RING)
as
s
hown in the di
a
gr
a
m.
Hardwired Zone Connections
- One EOLR
su
pervi
s
ed zone
su
pport
s
b
oth open circ
u
it
a
nd clo
s
ed circ
u
it device
s
a
nd h
as
a
re
s
pon
s
e time of
3
50m
s
ec. M
a
xim
u
m zone re
s
i
s
t
a
nce:
3
00 ohm
s
,
pl
us
EOLR
Note:
The h
a
rdwire zone c
a
nnot
b
e
us
ed
as
a
fire zone.
HARDWIRED ZONE: If the EOLR is not at the end of the
loop, the zone will not be properly supervised, and the
system may not respond to an open circuit on the zone.
C
u
t the incoming RING
a
nd TIP phone line
s
(typic
a
lly red
a
nd
green, re
s
pectively)
a
nd connect them to RJ
3
1X termin
a
l
s
4
(red)
a
nd 5 (green).
Connect the premi
s
e
s
end of the c
u
t RING
a
nd TIP wire
s
to
RJ
3
1X termin
a
l
s
1 (grey)
a
nd
8
(
b
rown) re
s
pectively.
Wire the flying le
a
d
s
of
a
Direct Connect Cord to the control'
s
phone termin
a
l
s
as
s
hown in the di
a
gr
a
m.
Pl
u
g the Direct Connect Cord into the RJ
3
1X j
a
ck.
Full Line Seizure:
The control m
us
t
b
e pl
a
ced in
s
erie
s
with the
incoming phone line. Pl
u
gging the Direct Connect Cord directly into
the RJ
3
1X j
a
ck,
a
llow
s
the control to
s
eize the phone line when
a
n
a
l
a
rm occ
u
r
s
a
nd norm
a
l phone line
usa
ge
b
y the premi
s
e
s
phone
s
if the pl
u
g need
s
to
b
e removed.
Connect termin
a
l EGND to
a
good e
a
rth gro
u
nd
as
s
hown on the
Su
mm
a
ry of Connection
s
.
Connect
s
en
s
or
s
/cont
a
ct
s
to the h
a
rdwired zone termin
a
l
s
GND
(-)
a
nd HWZ1 (+). Refer to the
Su
mm
a
ry of Connection
s
di
a
gr
a
m.
Connect clo
s
ed circ
u
it device
s
in
s
erie
s
in the high (+)
s
ide of
the loop. The EOL re
s
i
s
tor m
us
t
b
e connected in
s
erie
s
with the
device
s
, following the l
as
t device.
Connect open circ
u
it device
s
in p
a
r
a
llel
a
cro
ss
the loop. The
2000-ohm EOLR m
us
t
b
e connected
a
cro
ss
the loop
a
t the l
as
t
device.
AC Power Connections
- Connect the Power
Su
pply to the
recept
a
cle on the Control.
OR
Connect wire
s
from the Power
Su
pply to +9VDC
a
nd EGND
termin
a
l
s
as
s
hown on the
su
mm
a
ry of connection
s
di
a
gr
a
m.
WIRE
GAUGE
MAXIMUM DISTANCE BETWEEN
POWER SUPPLY AND CONTROL
Up to 11 feet
Up to 20 feet
Up to 26 feet
# 22
# 20
# 1
8
WIRING TABLE
FULL LINE SEIZURE CONNECTIONS
RJ31X
1
2
3
4
5
6
7
8
RING
TIP
INCOMING
PHONE LINE
TO
PREMISES PHONES
INCOMING
PHONE LINE
TO
PREMISES
PHONES
GREEN
RED
GREY
BROWN
RING
TIP
DIRECT
CONNECT
CORD
H/
S
T
H/
S
R
RING
TIP
BR
O
W
N
GREY
RED
GREEN