LYNX Touch Installation and Setup Guide
- 61 -
System Operation
Secondary User Codes
In normal operation mode, the Master Security Code can be used to assign up to 30 (L5200/L5200CN) or 46
(L7000/L7000CN) secondary 4-digit security codes, including a Guest Code and a Duress Code. The Master
Code can also be used to remove secondary codes from the system (individually). Refer to the LYNX Touch
User Manual for additional information.
Reset Master User Code
1.
After Entering the Installer Programming Mode, select “Reset Master Code” from the second page of the
Installer Programming Tools menu.
2.
The system displays a confirmation screen. Select the “Yes” key to reset the Master User Code to “1234”.
3.
If confirmed, the Master Code will be reset back to “1-2-3-4”. This will be logged in the System Event Log
as “Reset Master Code User 2 E655”. The system returns to the second page of the Installer
Programming Tools menu. OR
If the reset failed, the system will display: “Command Failed. Unable to Reset Master Code”.
Security Code Notes
•
The Master and Secondary security codes permit access to the system for arming, disarming, etc.
•
The Installer Code can disarm the system only if it was used to arm it. In addition, the Installer Code
cannot disarm the system if it was armed by pressing and holding a Quick-Arm button.
•
The Babysitter Code can disarm the system only if it was used to arm it. In addition, the Babysitter
Code cannot disarm the system if it was armed by pressing and holding a Quick-Arm button.
•
Duress code sends a special code to the monitoring station when used to perform any system operation.
Instruct users to be careful not to use this code for normal usage.
•
Opening/closing reports are sent for the Installer Code, with the appropriate subscriber number.
Master Code and set of secondary user codes are sent as Nos. 02 and 03–32 (L5200/L5200CN) or 03-48