Lynx Plus Series Installation and Setup Guide
- 8 -
Wiring Connections
c. Wire the flying leads of a Direct Connect Cord to the control’s phone terminals as shown in the diagram or plug into
the 8-position jack.
d. Plug the Direct Connect Cord into the RJ31X jack.
RJ31X
1
2
3
4
5
6
7
8
RING
TIP
INCOMING
PHONE LINE
TO
PREMISES PHONES
TIP RING TIP RING
BR
O
W
N
GREY
RED
GREEN
INCOMING
PHONE LINE
TO
PREMISES
PHONES
}
}
GREEN
RED
GREY
BROWN
RING
TIP
DIRECT
CONNECT
CORD
OR
OR
8-POSITION
JACK
01000-008-V0
Full Line Seizure Connections
UL
UL
UL
UL
The local sounder disable switch must be set to “ON” position.
External sounders and powerline carrier devices have not been evaluated by UL
LOCAL SOUNDER DISABLE: The Master Keypad’s built-in piezo sounder can be disabled by setting the
sounder disable switch to OFF. If disabled, however, no sounding will occur upon AC loss, since the
external sounder does not operate when AC power is lost.
HARDWIRED ZONE: If the EOLR is not at the end of the loop, the zone will not be properly supervised, and the
system may not respond to an open circuit on the zone.
3.
Hardwired Zone Connections
Zone 1 is an EOLR supervised zone that supports both open circuit and closed circuit devices and has a response
time of 350msec. Maximum zone resistance: 300 ohms, plus EOLR
Note:
The hardwire zone cannot be used as a fire or CO zone.
a. Connect sensors/contacts to the hardwired zone terminals 6 (-) and 7 (+). Refer to the Summary of Connections
diagram.
b. Connect closed circuit devices in series in the high (+) side of the loop. The EOL resistor must be connected in
series with the devices, following the last device.
c. Connect open circuit devices in parallel across the loop. The 2000-ohm EOLR must be connected across the loop
at the last device.
4.
Make External Sounder Connections
-
The control panel a 6-14VDC bell (120mA max.; e.g. ADEMCO WAVE2EX).
a. Connect a bell to terminals 8 (-) and 9 (+).
5.
Disable Local Sounder Option
- If required, the Master Keypad’s built-in piezo sounder can be disabled.
a. Set the Local Sounder Disable Switch to OFF.
6.
Make Powerline Carrier Device Connections
-
The control panel supports up to 8 Powerline Carrier Devices. If using
these devices, they must be connected to the control via a K10145X10 transformer.
a. Connect the com/data/sync/ lines from the K10145X10 transformer to the Powerline Carrier Device Connector using
the provided cable.
Refer to the
✻
✻
✻
✻
80 Device Programming Menu Mode section to program the Powerline Carrier Devices.