Data Field Descriptions
33
33
33
33
ALRM
ALRM
ALRM
ALRM SND
SND
SND
SND TIMEOUT
TIMEOUT
TIMEOUT
TIMEOUT
Alarm Bell Timeout
This field determines whether the external sounder will shut off after a selected time, or
allowed to continue until manually turned off.
UL installations:
must be set for a minimum of 4 min (option 1)
SELECTIONS
0 = No timeout
2 = 8 minutes
4 = 16 minutes
1 = 4 minutes
3 = 12 minutes
Fields
✻
34–
✻
36:
Fields *34, *35 and *36 are used to program different options in the Lynx Plus and LynxSIA Plus
controls. Please be sure that you use the correct field for the control being installed.
Note:
The LynxSIA Plus control validates the data entered in fields *34 - *36. If the selection is not valid the control will emit a
single long beep indicating that the selection has been rejected. The control replaces the selection with the default
value which is displayed on the keypad and advances to the next field.
34
34
34
34
EXIT
EXIT
EXIT
EXIT DELAY
DELAY
DELAY
DELAY TIME
TIME
TIME
TIME
Exit Delay
The system will wait the time entered before sounding an alarm if the exit door is left
open after the system has been armed.
UL installations:
Exit Delay must be set for a maximum of 60 seconds
SIA:
Exit Delay must be set to a minimum of 45 seconds.
Lynx Plus SELECTIONS
LynxSIA Plus SELECTIONS
(Entries from 45-97)
00-99 = exit delay in seconds
Entered Value
Exit Delay in Seconds
45-96
97
45-96
120
35
35
35
35
ENTRY
ENTRY
ENTRY
ENTRY DEL
DEL
DEL
DELAY
AY
AY
AY 1111
Entry Delay 01
The system will wait the time entered before sounding alarm upon entering if system is
not disarmed.
UL installations:
The Entry Delay must be set for a maximum of 45 seconds
SIA
The Entry delay
must be set to a minimum of 30 seconds. The sum of entry delay 1,
entered in Field
✻
35, and the burglary abort window, entered in Field
✻
50, should
not exceed 1 minute.
Lynx Plus SELECTIONS
LynxSIA Plus SELECTIONS
(Entries from 30-99)
00-99 = entry delay in seconds
Entered Value
Entry Delay in Seconds
30-96
97
98
99
30-96
120
180
240
36
36
36
36
ENTRY
ENTRY
ENTRY
ENTRY DELAY
DELAY
DELAY
DELAY 2222
Entry Delay 02
The system will wait the time entered before sounding alarm upon entering if the
system is not disarmed.
UL installations:
must be set for a maximum of 45 seconds
SIA The Entry delay
must be set to a minimum of 30 seconds. The sum of entry delay 2
entered in Field
✻
36 and the burglary abort window entered in
✻
50 should not
exceed 1 minute.
Lynx Plus SELECTIONS
LynxSIA Plus SELECTIONS
(Entries from 30-99)
00-99 = entry delay in seconds
Entered Value
Entry Delay in Seconds
30-96
97
98
99
30-96
120
180
240