Lynx Plus Series Installation and Setup Guide
- 20 -
Data Field Descriptions
The following pages list all data fields in this Control (in numerical order). Use the blank programming form
to record the data for this installation. Specific fields include options for programming that are unique to
the LynxSIA Plus version. Note that both keypad LEDs flash while in Programming mode. The LynxSIA
Plus version validates the data entry for the Fields listed below. If data entered is not within valid range,
the control will emit a long beep indicating that entry is rejected and will substitute the default value for the
invalid entry. The default value will be displayed on the keypad, and the control advance to the next field.
Field
Name
Default Value
Valid Range
*34 Exit
Delay
60 45-97
*35
Entry Delay 01
30
30-99
*36
Entry Delay 02
30
30-99
*50
Burglary Dial Delay
2
1-3
*57
False Alarm Options
7
0-7
*59
Exit Error Report Code
1
1-F
*64
Test Report Code
10
10-FF
*68
Cancel Report Code
10
10-FF
*69
Recent Closing Report Code
1
1-F
*76
Test Restore Report
10
10-FF
*92 Swinger
Shutdown 1
1-2
Note:
Entering a number other than the one specified will give unpredictable results.
20
20
20
20
INSTALLER
INSTALLER
INSTALLER
INSTALLER CODE
CODE
CODE
CODE
Installer Code
The Installer Code is used to enter the 4-digit Master Security Code. See "Master Code"
in the
System Operation
section
for procedure.
Note:
LynxSIA Plus does not allow duplication of Installer code. If a duplicate code is
entered the entry is rejected and LYNX issues single long beep indicating rejection.
The old installer code remains unchanged.
SELECTIONS
Enter 4 digits (0-9)
21
21
21
21
QUICK
QUICK
QUICK
QUICK ARM
ARM
ARM
ARM ENABLE
ENABLE
ENABLE
ENABLE
Quick Arm Enable
If enabled, security code is not required to arm the system. The user simply presses and
holds down the AWAY or STAY key to arm.
SELECTIONS
0 = do not allow quick arm
1 = allow quick arm
22
22
22
22
KKKKEY
EY
EY
EYPPPPAAAADDDD BBBBACKLI
ACKLI
ACKLI
ACKLIGHT
GHT
GHT
GHT
Keypad Backlight Timeout
This option allows the choice of either always backlighting the keypad or turning the
backlighting off after 10 seconds of keypad inactivity.
SELECTIONS
0 = no timeout; always backlight keys
1 = turn backlighting off after inactivity
22223333
FORCED
FORCED
FORCED
FORCED
BYPASS
BYPASS
BYPASS
BYPASS
Forced Bypass
All zones bypassed by this function will be displayed after the bypass is initiated.
UL installations:
must be 0 (no forced bypass)
SELECTIONS
0 = no forced bypass
1 = provide automatic bypass of all open (faulted) zones
24
24
24
24
RF
RF
RF
RF HOUSE
HOUSE
HOUSE
HOUSE ID
ID
ID
ID CODE
CODE
CODE
CODE
RF House ID Code
The House ID identifies receivers and wireless keypads. If a 5804BD/5804BDV
Transmitter is to be used, a House ID Code MUST be entered, and the keypad should
be set to the same ID.
SELECTIONS
00 = disable all wireless keypad usage
01-31 = House ID