Lynx Plus Series Installation and Setup Guide
- 66 -
Troubleshooting Guide
C o n t r o l
SYMPTOM
POSSIBLE
CAUSE
REMEDY
1.
“No AC” is displayed.
1a. Interrupted AC power supply.
1a. Check transformer connection and
powerline circuit breaker.
2. Digital
communicator
message not being
received.
2a. System in Test mode.
2b. Telephone connection not secure.
2c. Digital
communicator
malfunctioning.
2d. Telephone number in program needs
prefix or access code.
2e. Telephone call to central monitoring
station requires operator assistance.
2a. Remove from Test mode.
2b. Check all connections.
2c. Check with a different CONTROL PANEL.
2d. Program prefix or access code into the
CONTROL PANEL.
2e. System cannot work in this situation.
3.
Does not arm
properly.
READY light
not on.
3a. Open or faulted zone(s)
3a. Check for faulted zones and make intact, or
use Bypass arming, if desired.
4. System
doesn't
respond to keystrokes
on keypad.
4a.
"CC"
displayed.
4b. "d1"
displayed.
4a. System is in communication with
downloader at central station.
4b. System has just been powered and is in
its one minute initialization.
4a. Wait until download session is finished.
4b. Wait for initialization to finish, or bypass
this time by pressing '#' + '0.'
Smoke Detectors
SYMPTOM
POSSIBLE
CAUSE
REMEDY
1.
Detector alarms, no
apparent reason.
1a. Dust, dirt in sensing chamber.
1b. Improper
location.
1c. Unit
malfunctioning.
1a. Clean unit's sensing chamber with vacuum
cleaner per unit's instructions.
1b. See unit's instructions for locations to avoid.
Relocate as necessary.
1c. Replace
detector.
2. Detector's
siren
sounds.
2a. Unit not receiving required power.
2b. Unit
malfunctioning.
2a. Check for proper installation of battery. Try new
battery.
2b. Replace
detector.