![Honeywell IF2 Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/honeywell/if2/if2_user-manual_148749040.webp)
30
IF2 Network Reader User Guide
Session
(EPCglobal Class 1 Gen 2 tags only) Sets the command session parameter to the
corresponding EPCglobal Class 1 Gen 2 air protocol command (default is Query-
Adjust).
This setting is equivalent to the SESSION BRI attribute. For more information on
this setting, see the EPCglobal Class 1 Gen 2 documentation.
Initial Q
(EPCglobal Class 1 Gen 2 tags only) Sets the initial Q parameter value used by the
Query command. Valid range is 0 to 15 (default is 4). If you know there is only one
tag in the field, set this attribute to 0 for best performance.
This setting is equivalent to the INITIALQ BRI attribute.
Initialization Tries
Sets the maximum number of times the reader attempts to initialize a tag. Valid
range is 1 (default) to 254.
This setting is equivalent to the INITTRIES BRI attribute.
Schedule Option
Determines how antennas are switched during the inventory process. This attri-
bute controls the behavior of the inventory scheduling parameters.
This setting is equivalent to the SCHEDULOPT BRI attribute.
ID Tries
Sets the maximum number of times the reader executes the identify algorithm
before a response is returned to a Read or Write command.
In practice, this is the number of times a tag ID attempt is made for each antenna
being used. Valid range is 1 to 254 (default is 3).
This setting is equivalent to the IDTRIES BRI attribute.
Antenna Tries
Sets the maximum number of ID Tries that the reader executes per antenna. Valid
range is 1 to 254 (default is 3).
This setting is equivalent to the ANTTRIES BRI attribute.
EPCC1G2 Advance Medium Access Mode
Selects low-level protocol (such as tari and back-link frequency) settings. If you are
using CAEN tags, you must enable this mode before the tags can be read.
Содержание IF2
Страница 1: ...User Guide IF2 Network Reader ...
Страница 8: ...vi IF2 Network Reader User Guide ...
Страница 10: ...viii IF2 Network Reader User Guide ...
Страница 34: ...24 IF2 Network Reader User Guide ...
Страница 52: ...42 IF2 Network Reader User Guide ...
Страница 75: ......
Страница 76: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 935 040 004 Rev A 08 18 ...