IF2 Network Reader User Guide
29
•
For EPC tags, the identifier corresponds to EPCID.
Check the check box to enable tag ID reporting. This setting is equivalent to the
IDREPORT BRI attribute, and is enabled by default.
No Tag Report
Enables or disables a NOTAG message, which is sent when no tags are found
during execution of a Read, Write, or Lock command. Check the check box to
enable the message. This setting is equivalent to the NOTAGRPT BRI attribute, and
is enabled by default.
Report Timeout
Sets the timeout (in ms) for delays in tag reporting when the IF2 is in continuous
read mode. Range is 0 (default) to 65534.
Timeout Configuration Mode
Enables a timeout mode. Instead of specifying the number of antenna or ID tries,
you specify an antenna or ID timeout value. If the IF2 does not find any tags after
an antenna or ID try, the reader waits this long before starting the next antenna or
ID try. If you enable timeout mode, you need to set the ID Timeout and Antenna
Timeout values.
This setting is equivalent to the TIMEOUTMODE BRI attribute, and is disabled by
default.
To enable Timeout Configuration mode:
1. Check the check box. The screen refreshes. The Antenna Tries setting is
replaced by Antenna Timeout, and the ID Tries setting is replaced by ID Time-
out.
2. Specify the value (in ms) for the antenna or ID timeout in the entry fields and
then click
Activate Changes
.
For more information on ID Timeout and Antenna Timeout, see those topics later in
this section.
Select Tries
(Not supported by EPCglobal Class 1 Gen 2 tags) Sets the number of times a group
select is attempted. A group select is the command that starts the identity process.
Valid range is 1 (default) to 254.
This setting is equivalent to the SELTRIES BRI attribute.
Unselect Tries
(Not supported by EPCglobal Class 1 Gen 2 tags) Sets the number of times a group
unselect is attempted. Valid range is 1 (default) to 254.
Содержание IF2
Страница 1: ...User Guide IF2 Network Reader ...
Страница 8: ...vi IF2 Network Reader User Guide ...
Страница 10: ...viii IF2 Network Reader User Guide ...
Страница 34: ...24 IF2 Network Reader User Guide ...
Страница 52: ...42 IF2 Network Reader User Guide ...
Страница 75: ......
Страница 76: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 935 040 004 Rev A 08 18 ...