![Honeywell HERMetic UTImeter Gtex Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/honeywell/hermetic-utimeter-gtex/hermetic-utimeter-gtex_operation-and-service-manual_152332006.webp)
50461/GTEX MMC/1111
6
UTImeter Gtex MMC
3.5 Certification
The equipment has been approved for the
electrical intrinsic safety by the following
authorities :
IECEx
Zone 0 Ex ia IIB T4 20°C < Ta < +50°C
Standards used:
IEC 600790, Fourth Edition 200401,
IEC 6007911, Fifth Edition 200607
IEC 6007926, First Edition 200403
ATEX
II 1 G EEx ia IIB T4 / Tamb. 50 °C
Standards used:
EN50014, (1997) + Amds 1 & 2
EN50020,
(2002)
EN50284,
(1999)
Regarding product compliance against standards
updates or new standards, please refer to the
Declaration of conformity.
Factory Mutual (FM Approvals)
CL I, DIV 1, GP C&D, T4
Tamb. 50 °C and
CL I, ZN 0, AEx ia IIB T4
Tamb. 50 °C
The equipment has been approved as oil/water
interface detector according to MARPOL
Resolution MEPC.5(XIII) of 13 June 1980 by
National Maritime Authorities and/or Classification
Societies.
If you need a copy of any of these certificates
please contact:
Enraf Tanksystem SA
Rue de l'industrie 2
1630 Bulle, SWITZERLAND
Telephone
: +41-26-91 91 500
Telefax
: +41-26-91 91 505
Web site
: www.tanksystem.com
E-mail :
3.6 Spare
parts
When ordering spares identify the spare part by
TS number and description. Refer to section
“Drawings”.
Some spares might be repairable; in this case
send the part(s) to any authorised service center
or to the factory.
In case of urgency, complete replacement units
can be made available. Contact the factory or
nearest Service Station for details.
3.7
Service and Repair
The customer is responsible for any freight and
customs clearance charges. If units are sent on a
"freight collect" the charges will be invoiced to the
customer.
When returning units or parts for repair to the
factory please fill out a service request form (see
next page). The serial number (letter "G" followed
by 5 digits) is printed on the identification plate as
shown on the Figure 2-1.
When returned to Enraf Tanksystem SA
equipment must be contamination-free. If it is
determined that the customers equipment is
contaminated, it will be returned to the
customer at the customers expense.
Contaminated equipment will not be repaired
until such time that the customer
decontaminates the said equipment.
Enraf Tanksystem SA is
an ISO 9001 certified
company by QMI and
MED-D by Det Norske
Veritas Certification
GmbH.
Содержание HERMetic UTImeter Gtex
Страница 10: ...50461 GTEX MMC 1111 UTImeter Gtex MMC 10 ...
Страница 54: ...50461 GTEX MMC 1111 UTImeter Gtex MMC 54 Figure 13 2 display unit assembly TS 10210 details ...
Страница 57: ...50461 GTEX MMC 1111 UTImeter Gtex MMC 57 Figure 13 5 load details ...
Страница 63: ......
Страница 64: ......