UTImeter Gtex MMC
41
10.5 Sensing probe replacement
THE REPLACEMENT OF THE SENSING
PROBE DOES NOT REQUIRE TO RE-
CALIBRATE THE TEMPERATURE NOR THE
ULLAGE / INTERFACE.
10.5.1 Disconnecting the old sensing probe
Unscrew the securing screw with the 1.5 mm
Hex Allen key.
Pull carefully the adaptor out of the sensing
probe tube by turning it slightly left and right.
Make sure that the O-ring is not damaged
when it passes the hole of the sensing probe
tube.
Disconnect the plug by pulling it gently out of
the tube.
10.5.2 Connecting the new sensing probe
Refer to Figure 10-9.
Insert the 1.5 Allen key gently in the free hole
in the middle of the tape plug.
With one hand keep the sensing probe and the
tape adaptor as shown on Figure 10-9.
With the other hand drive the plug into the new
sensor tube with the 1.5 Allen key to connect it
to the sensing probe socket. Note this is a one
way only plug. The wires shall be on the
opposite side of the electronic circuit print as
shown on Figure 10-9.
Pull out gently the 1.5 Allen key from the plug
while keeping the plug in place with another
non sharp tool, for instance the 4 mm Allen
key. Check that the plug is fully inserted.
Switch on the unit and wait a few seconds. If
all is OK, the temperature is displayed and the
buzzer beeps every 2 seconds. If there is any
problem, refer to the section 11 "Trouble
shooting".
Put some light grease on the O-ring.
Push gently the adaptor into the sensing probe
tube. Mind not to damage the O-ring when it
passes the screw hole.
Screw the securing screw back with the 1.5
mm Hex Allen key.
thread for securing screw
O-ring
sensor tube
one-way only plug
tape wires
tape adaptor
tape
1.5 mm Allen key
Figure 10-9
10.6 Tape wipers replacement
The 2 tape wipers can be easily replaced:
Check that the tape cleaner is on "DOWN"
position.
Unlock and remove the housing lid.
The tape wipers are inserted in holders
grooves. Remove the old ones and insert the
new ones.
Put back and lock the housing lid
Check that the tape cleaner is working
properly.
Note:
we recommend to change always both
wipers.
wipers
Figure 10-10