FINAL INSTALLATION

Figure 4.2

Figure 5.2

Figure 4.1

Figure 5.1

Figure 4.3

Figure 5.3

WARNING:

 Do NOT wire the  

fan motor to a variable-speed 

(dimmer) wall control. 

Mounting 

Bracket Screw

1. Use wire connnectors to connect household supply and fan wires according to the diagram (Figure 5.1) and the following 

steps:

• Connect the green wire from the downrod and mounting bracket to the Bare/Green (ground) supply wire. 

Note: 

Closemount 

installation does not use the downrod, so there will only be two Green wires to connect. 

• Connect the White wire from the fan to the White (neutral) supply wire.

• Connect the Black and Blue wires from the fan to the Black (hot) supply wire.

Note:

 If there is a second hot supply wire in the outlet box, connect it to the blue (light power) fan wire for separate light and 

fan control. 

2. Align the canopy over the loosened mounting bracket screws. Place the J-slot of the canopy onto the mount bracket screws 

and rotate clockwise (Figure 5.2).

3. Secure the canopy with the two previously removed mounting bracket screws. Tighten all the mounting bracket screws 

securely (Figure 5.3). 

Canopy Cover

Wire Connector

Closemount 

Screw

Mounting 

Bracket

Canopy

Canopy

Canopy

Hook

CLOSEMOUNT INSTRUCTIONS

 (optional)

1. Remove the canopy cover from the bottom of the canopy (Figura 4.1). 

2. Remove the three Phillips-head closemount screws from the top of the motor assembly. Then align the canopy with the holes 

in the top of the motor assembly. The larger holes in the canopy will encompass the remaining screws. Secure the canopy to 

the top of the motor assembly with the previously removed closemount screws (Figura 4.2).

3. Raise the motor assembly and place the canopy on the hook of the mounting bracket to free hands during the wiring process 

(Figura 4.3). 

Mounting 

Bracket Screw

Black (hot)

White (neutral)

Bare/Green

(ground)

Black

Blue

Whit

e

Green

Содержание Glencrest

Страница 1: ...Glencrest Ceiling Fan User Guide ome RATED FOR DAMP CONDITIONS ...

Страница 2: ...otor Assembly Set Screw x 2 Light Pan Screw x 3 Fitter Plate Screw x 3 Blade Arm x 5 Bulb x 3 Fitter Plate Light Kit Light Pan Motor Screw x 10 Finial Cap Finial Glass Bowl Blade Balancing Kit Blade Washer x 15 Blade Screw x 15 Wire Connector x 3 Pull Chain Extension x 2 Note Some extra hardware may be included The quantity listed above is the number required for installation ...

Страница 3: ...n 12 gauge and or there is more than one house wire to connect to the two fan lead wires consult an electrician for the proper size wire connectors to use WARNING To reduce the risk of fire electric shock or personal injury do not bend the blade arms when installing them balancing the blades or cleaning the fan Do not insert objects between the rotating fan blades WARNING To reduce the risk of per...

Страница 4: ...ling angle is not steeper than 16 degrees Flushmount Installation not available for this model Closemount Installation best suited for ceilings 8 feet or lower 3 Choose a suitable location Ensure the blades will be at least 30 inches from any obstructions Also check the downrod length to ensure the blades will be at least 7 feet above the floor Figure 1 3 1 Loosen all four mounting bracket screws ...

Страница 5: ...to simplify wiring After pulling the wires all the way through the downrod measure 8 inches of wire Cut off the excess wire using wire cutters not included Then strip 1 2 inch of insulation from the end of each wire strand Figure 3 4 5 Install the ball end of the downrod into the opening of the mounting bracket Figure 3 5 WARNING Failure to align the slot in the ball with the tap on the mounting b...

Страница 6: ...over the loosened mounting bracket screws Place the J slot of the canopy onto the mount bracket screws and rotate clockwise Figure 5 2 3 Secure the canopy with the two previously removed mounting bracket screws Tighten all the mounting bracket screws securely Figure 5 3 Canopy Cover Wire Connector Closemount Screw Mounting Bracket Canopy Canopy Canopy Hook CLOSEMOUNT INSTRUCTIONS optional 1 Remove...

Страница 7: ...fitter plate and loosen the other two Then lift the light pan and place the two keyhole slots in the light pan over the two loosened fitter plate screws Turn the light pan in a clockwise direction and secure it using the previously removed fitter plate screw Tighten all three fitter plate screws Figure 5 6 7 Remove one of the three light pan screws from the light pan and loosen the other two screw...

Страница 8: ... 5 11 Figure 5 10 Figure 5 12 Fan Pull Chain Reverse Switch Light Pull Chain Glass Bowl Rubber Washer Hex Nut Finial Cap Finial Figure 6 2 Figure 6 1 Reverse Switch Reverse Switch Light Pull Chain Fan Pull Chain OPERATING INSTRUCTIONS 1 The fan pull chain has four positions to control fan speed One pull is high two is medium three is low and four turns the fan off The light pull chain has two posi...

Страница 9: ... to the outlet box and that the screws are tight 1 Ensure the 9 pin connectors are properly secured 2 Turn the power off and check all connections at the ceiling outlet box 1 Check and tighten all screws that hold the fan blades to the blade arms and the blade arms to the motor 2 Switch one blade with a blade from the opposite side or balance the fan using the blade balancing kit 3 Turn off the po...

Страница 10: ...rms stated above shall not be liable for any loss or damage of any kind including any incidental or consequential damages resulting directly or indirectly from any breach of warranty express or implied or any other failure of this product Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you If the original purchaser cea...

Отзывы: