background image

7

FINAL INSTALLATION

Figure 5.5

Figure 5.9

Figure 5.4

Figure 5.8

Figure 5.7

Figure 5.6

Finial

Light Kit

Bulb

Motor Screw

Light Kit

Fitter Plate Screw

Blade Screw

Blade Washer

Blade Arm

Blade

9-pin Connector

Blade Arm

Light Pan

Fitter Plate

Fitter Plate Screw

  4. Partially insert the blade screws along with blade washer through blade and into the blade arm. Tighten each blade screw 

starting with the one in the middle. Repeat this step for the remaining blades and blade arms (Figure 5.4). 

  5. Install the blade arm to the underside of the motor assembly using the ten previously removed motor screws (Figure 5.5).

  6. Remove one of the three fitter plate screws from the fitter plate and loosen the other two. Then lift the light pan and place 

the two keyhole slots in the light pan over the two loosened fitter plate screws. Turn the light pan in a clockwise direction and 

secure it using the previously removed fitter plate screw. Tighten all three fitter plate screws (Figure 5.6).

  7. Remove one of the three light pan screws from the light pan and loosen the other two screws. Then, connect the 9-pin 

connector from the fan to the 9-pin connectors from the light kit. Align the screw holes of the light kit over the loosened light 

pan screws and turn in a clockwise direction. Replace previously removed light pan screw. Tighten all screws (Figure 5.7).

  8. Install the three E26-base LED bulbs (Figure 5.8).

  9. Remove the finial, finial cap, hex nut, and rubber washer from the threaded rod on the light kit (Figure 5.9).

Rubber Washer

Hex Nut

Finial Cap

Содержание Glencrest

Страница 1: ...Glencrest Ceiling Fan User Guide ome RATED FOR DAMP CONDITIONS ...

Страница 2: ...otor Assembly Set Screw x 2 Light Pan Screw x 3 Fitter Plate Screw x 3 Blade Arm x 5 Bulb x 3 Fitter Plate Light Kit Light Pan Motor Screw x 10 Finial Cap Finial Glass Bowl Blade Balancing Kit Blade Washer x 15 Blade Screw x 15 Wire Connector x 3 Pull Chain Extension x 2 Note Some extra hardware may be included The quantity listed above is the number required for installation ...

Страница 3: ...n 12 gauge and or there is more than one house wire to connect to the two fan lead wires consult an electrician for the proper size wire connectors to use WARNING To reduce the risk of fire electric shock or personal injury do not bend the blade arms when installing them balancing the blades or cleaning the fan Do not insert objects between the rotating fan blades WARNING To reduce the risk of per...

Страница 4: ...ling angle is not steeper than 16 degrees Flushmount Installation not available for this model Closemount Installation best suited for ceilings 8 feet or lower 3 Choose a suitable location Ensure the blades will be at least 30 inches from any obstructions Also check the downrod length to ensure the blades will be at least 7 feet above the floor Figure 1 3 1 Loosen all four mounting bracket screws ...

Страница 5: ...to simplify wiring After pulling the wires all the way through the downrod measure 8 inches of wire Cut off the excess wire using wire cutters not included Then strip 1 2 inch of insulation from the end of each wire strand Figure 3 4 5 Install the ball end of the downrod into the opening of the mounting bracket Figure 3 5 WARNING Failure to align the slot in the ball with the tap on the mounting b...

Страница 6: ...over the loosened mounting bracket screws Place the J slot of the canopy onto the mount bracket screws and rotate clockwise Figure 5 2 3 Secure the canopy with the two previously removed mounting bracket screws Tighten all the mounting bracket screws securely Figure 5 3 Canopy Cover Wire Connector Closemount Screw Mounting Bracket Canopy Canopy Canopy Hook CLOSEMOUNT INSTRUCTIONS optional 1 Remove...

Страница 7: ...fitter plate and loosen the other two Then lift the light pan and place the two keyhole slots in the light pan over the two loosened fitter plate screws Turn the light pan in a clockwise direction and secure it using the previously removed fitter plate screw Tighten all three fitter plate screws Figure 5 6 7 Remove one of the three light pan screws from the light pan and loosen the other two screw...

Страница 8: ... 5 11 Figure 5 10 Figure 5 12 Fan Pull Chain Reverse Switch Light Pull Chain Glass Bowl Rubber Washer Hex Nut Finial Cap Finial Figure 6 2 Figure 6 1 Reverse Switch Reverse Switch Light Pull Chain Fan Pull Chain OPERATING INSTRUCTIONS 1 The fan pull chain has four positions to control fan speed One pull is high two is medium three is low and four turns the fan off The light pull chain has two posi...

Страница 9: ... to the outlet box and that the screws are tight 1 Ensure the 9 pin connectors are properly secured 2 Turn the power off and check all connections at the ceiling outlet box 1 Check and tighten all screws that hold the fan blades to the blade arms and the blade arms to the motor 2 Switch one blade with a blade from the opposite side or balance the fan using the blade balancing kit 3 Turn off the po...

Страница 10: ...rms stated above shall not be liable for any loss or damage of any kind including any incidental or consequential damages resulting directly or indirectly from any breach of warranty express or implied or any other failure of this product Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you If the original purchaser cea...

Отзывы: