20" WHOLE HOUSE WINDOW FAN

20" (50.8 cm) MODEL 3C614F/9166F

 

MODEL  

 

3C614F/9166F

  SPEED HIGH 

MED 

LOW

  CFM  

3560 

3120 

2510

 M

3

/s  

1.68 

1.47 

1.18

  RPM  

1600 

1450 

1100

  Amps   1.4 

1.2 

1.0

  Watts    170 

145 

115

  dB A 

 64 

57 

50

MODEL/MODELO/MODELE 3C614F/9166F

DESCRIPTION

The Air King® 20" (50.8 cm) Whole House Window Fan features three 
intake and three exhaust speeds. Fan will fit windows 27" (68.6 cm) to 
38" (96.5 cm) wide x 26-1/4" (66.7 cm) high. The adjustable side panels 
are designed to accommodate Fan mounting either inside or outside 
interior window trim. The 3-paddle Fan blade is driven by a permanently  
lubricated, permanent split capacitor motor with 6' (1.8 m), 18/3 cord 
set.

SPECIFICATIONS

Motor  ...................................... 120V, 60 Hz 
Blade diameter ....................... 20" (50.8 cm)
Speeds .................................... 3 Intake, 3 Exhaust
Control .................................... Rotary Switch
Approvals ................................ ETL Listed. Close mesh Fan guard
 

meets OSHA requirements.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions 

should always be followed to reduce the risk of fire, 

electric shock and injury to person, including the 

following:

1.  Read all instructions before using Fan.  

2.    Make certain that the power source conforms to the electrical 

requirements of the Fan.

3.  Use this Fan only as described in this manual.  Any other use 

not recommended by the manufacturer may cause fire, electrical 

shock, or injury to persons.

4.  Unplug power cord before installing, servicing, or moving the 

Fan.

WARNING:

 

DO NOT DEPEND UPON THE ON-OFF 

SWITCH AS THE SOLE MEANS OF DISCONNECTING 
POWER WHEN INSTALLING OR SERVICING THE FAN.  
ALWAYS UNPLUG THE POWER CORD.

5.  This Fan must NOT be used in potentially dangerous 

locations such as flammable, explosive, chemical-laden 

or wet atmospheres.

6. The power cord is equipped with a three-prong grounded plug 

that must be inserted into a matching receptacle.  Under no 

circumstances should the grounding prong be cut off the plug.  

Where a two-prong wall receptacle is encountered, it must 

be replaced with a properly grounded three-prong receptacle 

installed in accordance with the National Electrical Code (NEC) 

and all applicable local codes and ordinances.  This work must 

be done only by a qualified electrician, using copper wire only. 

Contact your Grainger Distributor.

WARNING:

 USE OF A THREE-PRONG TO TWO-PRONG 

ADAPTER IS NOT RECOMMENDED.  IMPROPER CONNEC-
TION MAY CREATE THE RISK OF ELECTROCUTION.  USE 
OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA.

7.  Where possible, avoid the use of extension cords.  If they must 

be used, minimize the risk of overheating by ensuring that they 

are UL listed.  Never use a single extension cord to operate 

more than one Fan.

8.  Do not operate any Fan with a damaged cord or plug or 

after the Fan malfunctions, has been dropped or damaged 

in any manner.  Return Fan to authorized service facility for 

examination, electrical or mechanical adjustment or repair.

9.  Do not insert or allow fingers or foreign objects to enter any 

ventilation or exhaust opening as it may cause an electric shock 

or fire, or damage the Fan.  Do not block or tamper with the 

Fan in any manner while it is in operation. 

10.Always place the Fan on a stable, flat, level surface when 

operating to avoid the chance of the Fan overturning. Locate 

the Power Cord so the Fan or other objects are not resting on 

it. Do not run cord under carpeting. Do not cover cord with 

throw rugs, runners, or similar coverings. Do not route cord 

under furniture or appliances. Arrange cord away from traffic 

area and where it will not be tripped over.

11.This Fan is not intended for use in wet or damp locations.  

Never locate a Fan where it may fall into a bathtub or other 

water container.

12. Do not use Fan outdoors.

13.This Fan is not suitable for use in agricultural facilities including 

areas where livestock, poultry or other animals are confined. 

Please refer to National Electric Code (NEC) Article 547-7 

(2008), or applicable state or local codes or standards relating 

to electrical requirements for Agricultural Buildings. 

THIS FAN 

DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 

547-7 (2008).

14. This Fan is not suitable for use in hazardous locations. Please 

refer to National Electric Code (NEC) Article 500 or applicable 

state or local codes or standards relating to electrical 

requirements for Hazardous locations. 

THIS FAN DOES NOT 

MEET THE REQUIREMENTS OF NEC ARTICLE 500 (2008).

WARNING:

 

REDUCE THE RISK OF FIRE OR 

ELECTRIC SHOCK – DO NOT USE THIS FAN WITH ANY 
SOLID STATE SPEED CONTROL DEVICES.

SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DE-

SCRIBED.  PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.  FAILURE TO COMPLY 

WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

 RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.  

OPERATING INSTRUCTIONS & PARTS MANUAL

Rev. Q 4/14

8

2085109A

Rev. Q 4/14

1

2085109A

LISTE DES PIECES DE REMPLACEMENT

Cl

é

 

No de Pi

è

ce Description 

Qte

  1 

02030213 

Moteur Assemblage 

1

  2 

2090008 

Vis #8 x 1,27 cm de type PPH 25 ZP 

24

  3 

5097005BK 

Grille intérieure 

1

  4 

5090045 

Vis #10-32 x 1,27 cm HWH Serr F-ZP 

3

 5 

5082090BKB Lame 

1

 6  2010722UV  Bâti 

1

  7 

5097002BK 

Grille extérieure 

1

  8 

02084613 

Plaque centrale 

1

  9 

2060087 

Panneau latéral 

2

  10 

02090508 

Guide en caoutchouc 

4

 11  2060086 

Canal 

2

  12 

05010109 

Bouton de l’interrupteur 

1

  13 

5090044 

Vis de réglage 0,64 cm 28 x 0,95 cm 

1

  14 

2091413 

Vis à bois #8 x 1,91 cm 

4

 15  2084076 

Gabarit 

1

  16 

2090024 

Vis #8 x 1,91 cm PPH de type 25 ZP 

4

Содержание 3C614F

Страница 1: ... Fan with a damaged cord or plug or after the Fan malfunctions has been dropped or damaged in any manner Return Fan to authorized service facility for examination electrical or mechanical adjustment or repair 9 Do not insert or allow fingers or foreign objects to enter any ventilation or exhaust opening as it may cause an electric shock or fire or damage the Fan Do not block or tamper with the Fan...

Страница 2: ... THE EXPIRATION OF THE WARRANTY PERIOD Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so these exclusions or limitations may not apply to you This warranty gives you specific legal rights You may also have other rights which vary from state to state and province to province Proof of purc...

Страница 3: ...icos para lugares peligrosos ESTE VENTILADOR NO CUMPLE CON LOS REQUISITOS DEL ARTICULO 500 2008 LEA Y GUARDE ESTAS INSTRUCCIONES LÉALAS CUIDADOSAMENTE ANTES DE INTENTAR ARMAR INSTALAR OPERAR O DAR MANTENIMIENTO AL PRODUCTO DESCRITO PROTÉJASE A SÍ MISMO Y A LOS DEMÁS OBSERVANDO TODA LA INFORMACIÓN SOBRE SEGURIDAD NO SEGUIR LAS INSTRUCCIONES PODRÍA RESULTAR EN LESIONES PERSONALES Y O DAÑOS A LA PROP...

Страница 4: ... INFORMATION GÉNÉRALE DE SÉCURITÉ Lors de l utilisation d appareils électriques des précautions de base doivent toujours être prises pour réduire le risque d incendie de choc électrique et de blessure personnelle incluant ce qui suit 1 Lire toutes les instructions avant d utiliser ce Ventilateur 2 Assurez vous que la pièce est équipée d un détecteur de fumée fonctionnel 3 Utiliser ce Ventilateur u...

Отзывы: