Configuring the intrusion detection unit
gtap.genetec.com | Honeywell Galaxy Control Panel Integration Guide 5.2
31
EN.550.007-V5.2.C4(3) | Last updated: March 11, 2014
Set the
Function
for
input 2
to a desired function. This function is the action you want to
take when the connection between Security Center and the control panel is lost (for
example, the
26 - Log
function records in the event log that an input has been activated).
For more information about how to configure an input’s function, see “Option 52- Program
Zones” in the
Honeywell Galaxy Dimension Installer Manual
.
2
Create a link from
input 1
to a free latch timer.
Using the keypad, set the
Link Source
as
input 1
.
Set the
Link Destination
as the
Latch Timer
, and enter a latch timer value higher than
60 seconds.
Every time the Intrusion Manager messages input 1, the link is activated. When the link
is deactivated, the link timer counts down from the latch timer value. If the timer reaches
zero, it means the connection between Security Center and the panel is lost. This
activates the latch timer, which triggers another link.
For information about creating links on your control panel, see “Option 54 - Links” in the
Honeywell Galaxy Dimension Installer Manual
.
3
Create a second link from the latch timer to
input 2
.
Set the
Link Source
as the latch timer.
Set the
Link Destination
as
input 2
.
Configure the heartbeat connection in Security Center
1
From the
Intrusion detection
task in Config Tool, select the intrusion detection unit to
configure, and click the
Properties
tab.
2
From the
Heartbeat input
drop-down list, select the input to receive the heartbeat messages
from the Intrusion Manager.
NOTE
The input must be the one you configured as the
Link source
on the control panel
(
input 1
). See
"Configure the heartbeat connection on the control panel"
3
Click
Apply
.
4
Click the
Peripherals
tab.
5
Select the input you configured as the
Link source
on your panel (
input 1
).
6
At the bottom of the
Peripherals
tab, click
Edit the item
(
).
7
In the dialog box that opens, from the
Intrusion detection areas
drop-down list, select an
intrusion detection area to map to the input.
IMPORTANT
The intrusion detection area must be the same group the input is part of on the
control panel. For more information, see “52.10=Group” in the
Honeywell Galaxy Dimension
Installer Manual
.