Known issues
gtap.genetec.com | Honeywell Galaxy Control Panel Integration Guide 5.2
7
EN.550.007-V5.2.C4(3) | Last updated: March 11, 2014
Known issues
Galaxy Dimension control panel integration includes the following known issues.
Limitations
Galaxy Dimension control panel integration includes the following known limitations.
Issue
Description
82756
Some intrusion detection events are not supported in Security Center 5.2.
Limitation
Description
55922
If an input is triggered from Security Center (from triggered intrusion alarm or the
heartbeat monitoring feature), the input settings are overwritten with the values
configured in Security Center.
Workaround:
Make sure the input configuration is the same in Security Center as on
the control panel.
57661
The Galaxy Dimension control panel does not respond well to multiple input triggers
that occur within one second of each other. As a result, you may lose your connection to
Security Center.
Workaround:
Don’t trigger more than one input at a time.
56703
When you create custom events for the intrusion detection panel, the event list in the
Intrusion detection unit events
task in Security Desk is not automatically updated.
Workaround:
Delete the Intrusion detection unit events task, and create a new task.
56828
Delay Arming (master/perimeter) is not supported.
57040
For some input functions such as "Final" and "Intruder", the Galaxy Dimension control
panel does not send notifications to Security Center when the input state changes from
"Normal" to "Active". Therefore, these inputs should not be used for virtual zones.
Please note that not all inputs functions have been tested, there may be others that
behave in the same manner.
57484
Offline logs are not supported.
57485
Security Center does not support the Galaxy configuration “Re-ordering of the on-
board RIO, SW3, dip-switch 8”.
57491
When an expansion module is connected or disconnected from the Galaxy Dimension
panel, you are not notified of the corresponding input and output states in Security
Center.
57492
The Intrusion Manager role cannot report the “Entry delay started” control panel event.