11
This section gives suggested answers to typical problems that installers may encounter:
Problem
Solution
Display stays blank
Check that power is reaching the dock/table-top
stand.
Check that the power is connected correctly.
The evotouch fails when removed from
dock/table-top stand
Check that the batteries are fitted correctly.
Check the polarity of the batteries.
The temperature readout is not displayed
Check the binding and communication between
the evotouch and sensor.
If there is no remote sensor, check that Internal
Remote Sensor has been specified in the Zoning
Configuration.
If External Remote Sensor has been specified,
check that it is functioning correctly
Room temperature does not match setpoint
Check that the boiler is functioning correctly.
Check that the actuator is functioning correctly.
Check that a local override has not been applied.
Check that the zone has been programmed
correctly.
Technical data
Electrical
Power module
Input voltage: 230VAC ±10%
Output voltage: 4VDC ±0.2V, max 2.6W
Room unit power supply input
4VDC ±0.2V, max. 2.6W
Low voltage cable length (max)
10m, 1.0mm²; 5m, 0.5 mm²
Battery type (rechargeable)
Type AA 1.2V NiMH 2000-2400mAh
RF Communication
RF operation band
ISM (868.0 – 870.0) MHz, RX Class 2
RF communication range
30m in a residential building environment
Environmental & Standards
Operating temperature
0 to 40°C
Storage temperature
-20 to +50°C
Humidity
10 to 90% relative humidity non condensing
IP Protection Class
IP30
Mechanical
Dimensions
139 x 101 x 21mm (WxHxD)
Troubleshooting
ENGLISH