4
✓
✗
✗
Installation instructions for wall mounting
Standard EU
Schuko Wall box
Minimum
depth
40mm
Insert wires into power module, observing
correct polarity
Push power module into wallbox with mains
wiring to the rear
The power module can be installed in a
different location from the evotouch unit.
Disconnect low voltage cable from wallplate
terminal block and extend the connection by
up to
10m max.
using
1.0mm²
cable. If smaller
size cable is used the maximum distance will
reduce (e.g.
5m max
with
0.5mm²
cable).
Observe correct polarity when connecting the
extension cable. Power Supply Cable wires are
Red (+), Black(-).
Attention
: Exceeding the maximum cable
length could cause system malfunction!
Attach wallplate to wall box or surface
(Power module remote).
Optional spacer for surface
mounting.
1.2–1.5m
Position wall box at a height of 1.2m - 1.5m.
Caution: Isolate power supply and make safe before wiring
the unit to prevent electric shock and equipment damage.
Installation should be carried out by a competent person.
Wires should
protrude 55 mm
230V
~
mains.
230V
~
mains.
Use screwdriver
with 2.5mm
head
Remove
protective film
Knock out
required holes
Attach evotouch to
wallplate
Not used
DC
+ –
X Y