6
Binding
Guided Configuration binds each of the
control devices and sensors to evotouch, to
ensure that the wireless communication is
working correctly.
After binding each device, a prompt
shows whether binding was successful; for
example:
Binding can fail for the following reasons:
- The device is not switched on.
- The device is too far away.
- There are too many solid objects in the
path to the device.
Correct the problem and try again.
Editing names
During configuration you are given the
option of editing the names used to identify
the zones in the system. These are the
names seen by the user on the main Home
screen.
To edit a name the following screen is
displayed:
• Press
to delete characters.
• Press
ABC
to enter upper-case letters,
abc
to enter lower-case letters, or
123
to
enter digits.
• Press the blank key to enter a space.
• Press
DONE
when finished.
Configuring mixed applications
The Guided Configuration described on the
following pages assumes all your zones use
the same type of control. If you have a mixed
application, such as 5 zones with radiator
control and 3 zones with underfloor heating
control, you can set up the configuration as
follows:
• Use the Guided Configuration to
configure the 5 zones for radiator control.
• Use the
ADD ZONE
option to add the
3 zones for underfloor heating control;
see
Adding a zone
, page 9.
• Finally use the
SYSTEM
CONFIGURATION
menu
BINDING AND
RF TEST
option, doing the RF test for
each zone. For more information see the
Extended Installation Guide
.
Configuration – General Features