background image

G

Install the Scan Assembly and Lower Dome

3

1

2

Remove the plastic lens cap. Do not touch the lens.

Rotate and line up the scan assembly yellow label to the housing 
yellow label. Gently push the scan into the housing until the two guides 
lock/snap into the holes on the housing guides. 

Gently pull down on the assembly to ensure it has properly latched into 
place.

See

5

Rugged

Clip the lanyard from the lower dome to the mounting post in the housing.

Insert the trim ring and align the lower dome tab hooks with the 3 mounting posts on the housing. 
Twist to lock the lower dome into the housing. 

In-ceiling

Indoor and Outdoor Pendant

Clip the lanyard from the lower dome to the mounting post in the housing. 

Although the captive screw is installed correctly on the housing at the factory,
it is recommended that you check it is loosened slightly to ensure it is not in
the path of the lower dome gasket during the rest of the installation.

Confirm that the trim ring gasket is in place around the inner groove of the 
lower dome and then push the lower dome into the housing until it is sitting 
firmly along the bottom edge of the housing. Tighten the captive screws.

Clip the lanyard from the lower dome to the mounting post in the housing.

Align the 4 lower dome screws with the 4 housing screw holes. Press the lower 
dome into the housing and turn the security screws using the provided hex key.

1

2

1

2

1

2

Scan Assembly Installation - All Housing Types

Lower Dome Installations

Lanyard

G

Scan assembly 
locking guide 
(1 of 2)

Housing* locking guide 
with holes

*Pendant housing shown

Rotate and align yellow 
labels on housing and 
scan

trim ring gasket

Scan Assembly 
Installation

Lower dome

H

800-01115 Rev B (07-2009)

If the trim ring gasket has shifted from its correct placement, 

DO NOT

 stretch the gasket 

or the dome may not be sealed properly to protect it from dust and moisture, which may 
damage the ACUIX PTZ dome over time.

The trim ring gasket is pre-installed at the factory. It is only correctly 
installed in one direction and on one groove.

If you are replacing or adjusting this gasket, ensure you push it all the 
way down in the groove with the flat side of the trim ring gasket 
installed towards the inside of the groove and upper lip towards the 
upper edge of the groove.

Indoor and Outdoor Pendant Lower Dome Installations

H

3

V2 pendant housings and lower dome models 
MUST be installed with each other. For example, 
install  HDB00P0SW

V2

 with HDH00PD00

V2

.

4

See

Содержание equip acuix

Страница 1: ...de VCL RS485 Diamond Pelco P and Pelco D Depending on your specific system installation protocols other than IntelliBus may need to be configured 3 2 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 IntelliBus 38400 baud no parity OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON MAXPRO mode 9600 baud even parity OFF OFF ON OFF ON OFF OFF OFF OFF ON OFF OFF OFF OFF OFF ON VCL RS485 9600 baud no parity O...

Страница 2: ...ugged Ensure a 24 VAC 2 6 A power source is available 2 See Install the Mount Adapter or Bracket Use the hole pattern on the mount adapter or bracket to drill holes in the wall ceiling or roof Use the appropriate hardware for the mounting surface and follow all installation warnings and cautions on the first page To prevent water leakage with outdoor installations apply sealant to around all the h...

Страница 3: ... 9 meters 20 59 feet 18 meters 45 feet 14 meters 18 94 feet 28 meters 72 feet 22 meters 16 149 feet 45 meters 115 feet 35 meters 14 238 feet 73 meters 183 feet 56 meters 12 378 feet 115 meters 291 feet 89 meters Recommended Ethernet Power and Contact Cabling Type Recommended Cable Maximum Distance Ethernet CAT5 or better 328 feet 100 m Power 18 AWG 2 conductor vinyl jacket See gauge chart for each...

Страница 4: ...using Tighten the captive screws Clip the lanyard from the lower dome to the mounting post in the housing Align the 4 lower dome screws with the 4 housing screw holes Press the lower dome into the housing and turn the security screws using the provided hex key 1 2 1 2 1 2 Scan Assembly Installation All Housing Types Lower Dome Installations Lanyard G Scan assembly locking guide 1 of 2 Housing lock...

Страница 5: ...etworks can be divided into several smaller networks by subnetting When a network is subnetted you must specify a subnet mask which tells network devices which smaller network they belong to If the subnet mask is not properly configured the camera or dome may not be able to communicate with other devices on the network Default Gateway The default gateway address that connects the device to the net...

Страница 6: ... enter the password guest Click to log onto the ACUIX IP Web Client A signed version of ActiveX control is installed when you use the Web Client to discover connected devices for the first time If you have a previous version of IP ActiveX is installed you are prompted to upgrade to Honeywell secure ActiveX control 1 2 3 Open Internet Explorer Navigate to Tools Internet Options Security tab With In...

Отзывы: