Install the Housing
3
In-ceiling (Dropped or Hard Ceiling)
Indoor and Outdoor Pendant
Route field wiring from mount through top of housing.
To prevent threads from binding, wrap the threaded nipple with
Teflon® tape. Thread housing onto mount.
Rugged
Cut a 7 5/8” (194 mm) hole in ceiling using the template provided. Seal
perimeter to stop dust or debris from falling from ceiling. For dropped ceilings,
remove ceiling plate and place on dropped ceiling tile. Trim the tile and press
into the plate.
If required, secure an installer supplied safety cable to a building support. A
3/32” (2.5 mm) plastic coated aircraft cable is recommended.
Place tile (including the plate for dropped ceilings, part number 517082-7130)
and housing on the ceiling grid supports.
Insert through hole with wing tabs flat.
Rotate tabs clockwise to tighten against ceiling. Ensure the space between wing
tab and housing is greater than ceiling thickness, and the wing tabs are staggered
to different heights.
Install a 0.75” (19 mm) conduit fitting on the housing.
Place the gasket between the hole and the conduit fitting. Tighten the conduit
nut and ensure water tight.
Route the field wiring through the hole in the side of the housing. Secure the
housing to the mounting bracket.
D
1
2
3
1
3
2
2
B
1
2
C
Indoor pendant and in-ceiling:
Ensure a 24 VAC @ 2.0 A power source is available.
Outdoor pendant and rugged:
Ensure a 24 VAC @ 2.6 A power source is available.
2
See
Install the Mount, Adapter or Bracket
Use the hole pattern on the mount, adapter or bracket to drill holes
in the wall, ceiling or roof. Use the appropriate hardware for the
mounting surface and follow all installation warnings and cautions
on the first page.
To prevent water leakage with outdoor installations, apply sealant
to around all the holes between the mount, mount and the adapter,
and any mounting surface. For wall mount installations also
confirm that the pre-installed gasket on the base of the mount is in
place.
For rugged domes, the bracket can be installed at any angle from
0° to 90° with respect to the housing; ensure the housing itself is
positioned horizontally and parallel to the floor.
If required for rugged dome installations, secure an installer
supplied safety cable to a building support. A 3/32” (2.5 mm)
plastic coated aircraft cable is recommended.
Pendant and Rugged Installations Only
C
1
2
B
Mounting bracket
(included with
housing)
C
Rugged Dome Housing
with Mounting Bracket
Housing
B
Indoor and Outdoor Pendant
Ceiling mount
(indoor only)
Parapet or
roof mount
Wall mount
Corner adapter *
Pole adapter *
Indoor
Outdoor
Housing and Lower Dome
Lower dome
Mounts and Adapters
*
The corner and pole adapters can be used with
the pendant wall mount or the rugged bracket
3
4
800-01115 Rev B (07-2009)
The new V2 pendant housings and
lower dome models MUST be
installed with each other.
D
*For a dropped ceiling
use a ceiling plate
Indoor in-ceiling
housing
In-Ceiling Housing*
Lower dome
See