background image

Install the Housing

3

In-ceiling (Dropped or Hard Ceiling)

Indoor and Outdoor Pendant

Route field wiring from mount through top of housing. 

To prevent threads from binding, wrap the threaded nipple with 
Teflon® tape. Thread housing onto mount.

Rugged

Cut a 7 5/8” (194 mm) hole in ceiling using the template provided. Seal 
perimeter to stop dust or debris from falling from ceiling. For dropped ceilings, 
remove ceiling plate and place on dropped ceiling tile. Trim the tile and press 
into the plate. 

If required, secure an installer supplied safety cable to a building support. A 
3/32” (2.5 mm) plastic coated aircraft cable is recommended.

Place tile (including the plate for dropped ceilings, part number 517082-7130) 
and housing on the ceiling grid supports. 

Insert through hole with wing tabs flat. 

Rotate tabs clockwise to tighten against ceiling. Ensure the space between wing 
tab and housing is greater than ceiling thickness, and the wing tabs are staggered 
to different heights.

Install a 0.75” (19 mm) conduit fitting on the housing.

Place the gasket between the hole and the conduit fitting. Tighten the conduit 
nut and ensure water tight.

Route the field wiring through the hole in the side of the housing. Secure the 
housing to the mounting bracket.

D

1

2

3

1

3

2

2

B

1

2

C

Indoor pendant and in-ceiling: 

Ensure a 24 VAC @ 2.0 A power source is available.

Outdoor pendant and rugged: 

Ensure a 24 VAC @ 2.6 A power source is available.

2

See

Install the Mount, Adapter or Bracket

Use the hole pattern on the mount, adapter or bracket to drill holes 
in the wall, ceiling or roof. Use the appropriate hardware for the 
mounting surface and follow all installation warnings and cautions 
on the first page. 

To prevent water leakage with outdoor installations, apply sealant 
to around all the holes between the mount, mount and the adapter, 
and any mounting surface. For wall mount installations also 
confirm that the pre-installed gasket on the base of the mount is in 
place.

For rugged domes, the bracket can be installed at any angle from 
0° to 90° with respect to the housing; ensure the housing itself is 
positioned horizontally and parallel to the floor.  

If required for rugged dome installations, secure an installer 
supplied safety cable to a building support. A 3/32” (2.5 mm) 
plastic coated aircraft cable is recommended.

Pendant and Rugged Installations Only

C

1

2

B

Mounting bracket 
(included with 
housing)

C

Rugged Dome Housing 
with Mounting Bracket

Housing

B

Indoor and Outdoor Pendant

Ceiling mount 
(indoor only)

Parapet or 
roof mount

Wall mount

Corner adapter * 

Pole adapter *

Indoor

Outdoor

Housing and Lower Dome

Lower dome 

Mounts and Adapters

*

The corner and pole adapters can be used with 

the pendant wall mount or the rugged bracket

3

4

800-01115 Rev B (07-2009)

The new V2 pendant housings and 
lower dome models MUST be 
installed with each other.

D

*For a dropped ceiling 
use a ceiling plate

Indoor in-ceiling 
housing

In-Ceiling Housing*

Lower dome 

See

Содержание equip acuix

Страница 1: ...de VCL RS485 Diamond Pelco P and Pelco D Depending on your specific system installation protocols other than IntelliBus may need to be configured 3 2 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 IntelliBus 38400 baud no parity OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON MAXPRO mode 9600 baud even parity OFF OFF ON OFF ON OFF OFF OFF OFF ON OFF OFF OFF OFF OFF ON VCL RS485 9600 baud no parity O...

Страница 2: ...ugged Ensure a 24 VAC 2 6 A power source is available 2 See Install the Mount Adapter or Bracket Use the hole pattern on the mount adapter or bracket to drill holes in the wall ceiling or roof Use the appropriate hardware for the mounting surface and follow all installation warnings and cautions on the first page To prevent water leakage with outdoor installations apply sealant to around all the h...

Страница 3: ... 9 meters 20 59 feet 18 meters 45 feet 14 meters 18 94 feet 28 meters 72 feet 22 meters 16 149 feet 45 meters 115 feet 35 meters 14 238 feet 73 meters 183 feet 56 meters 12 378 feet 115 meters 291 feet 89 meters Recommended Ethernet Power and Contact Cabling Type Recommended Cable Maximum Distance Ethernet CAT5 or better 328 feet 100 m Power 18 AWG 2 conductor vinyl jacket See gauge chart for each...

Страница 4: ...using Tighten the captive screws Clip the lanyard from the lower dome to the mounting post in the housing Align the 4 lower dome screws with the 4 housing screw holes Press the lower dome into the housing and turn the security screws using the provided hex key 1 2 1 2 1 2 Scan Assembly Installation All Housing Types Lower Dome Installations Lanyard G Scan assembly locking guide 1 of 2 Housing lock...

Страница 5: ...etworks can be divided into several smaller networks by subnetting When a network is subnetted you must specify a subnet mask which tells network devices which smaller network they belong to If the subnet mask is not properly configured the camera or dome may not be able to communicate with other devices on the network Default Gateway The default gateway address that connects the device to the net...

Страница 6: ... enter the password guest Click to log onto the ACUIX IP Web Client A signed version of ActiveX control is installed when you use the Web Client to discover connected devices for the first time If you have a previous version of IP ActiveX is installed you are prompted to upgrade to Honeywell secure ActiveX control 1 2 3 Open Internet Explorer Navigate to Tools Internet Options Security tab With In...

Отзывы: