32
Troubleshooting
The following guide is for reference purposes only. Contact a customer service
representative to preserve the limited warranty terms.
SYMPTOMS
POSSIBLE CAUSE(S)
SOLUTION
All Interfaces
No LEDs, beep
or motor spin.
No power is being
supplied to the
scanner.
Check transformer, outlet and
power strip. Make sure the
cable is plugged into the
scanner.
No LEDs, beep.
No power is being
supplied to the
scanner from host.
Some host systems cannot
supply enough current to power
7600 series scanner. Use the
power supply included with the
scanner.
3 beeps on
power up.
Non-volatile RAM
failure.
Contact a customer service
representative, if the unit will not
hold the programmed
configuration.
Continuous
razz tone on
power up.
RAM or ROM failure.
Contact a customer service
representative, if the unit will not
function.
Razz tone and
amber LED flash
at power up.
VLD failure.
Contact a customer service
representative.
Razz tone and
both LEDs flash
at power up.
Scanner motor failure.
Contact a customer service
representative.
Multiple scans
upon
presentation of
code.
Same symbol timeout
set too short.
Adjust same symbol timeout for
a longer time.
The unit powers
up, but does
not beep.
Beeper disabled
No volume is selected
No tone is selected.
Enable beeper
Select volume
Select tone.
Содержание Dolphin 7600
Страница 1: ...Horizon 7600 Presentation Laser Imager Installation and User s Guide ...
Страница 26: ...22 Figure 22 Connector Orientation Figure 23 Secondary Scanner Setup ...
Страница 33: ...29 Figure 28 IR Activation Area Parallel to Package Flow Specifications are subject to change without notice ...
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 00 02870 Rev F 9 11 ...