Introduction
4
DirectLine® DL421 Sensor Module User Manual
2/04
1.5 Model Selection Guide
Instructions
Select the desired key number. The arrow to the right marks the selection available.
Make the desired selections from Tables I through IV using the column below the
proper arrow.
A dot ( ) denotes availability.
Key Number
I
II
III
IV
_ _ _ _ _
-
_
-
_
-
_
-
_ _ _ _
Key Number - DirectLine
®
Sensor Electronics Module
(Specify electrodes/cells/probes separately)
Selection
pH
For use with Durafet II, Meredian II & HPW7000 pH electrodes
DL421
ORP
For use with ORP electrode
DL422
Conductivity
For use with Contacting Conductivity Cells
DL423
DO - PPM
For use with Dissolved Oxygen ppm Probes
DL424
DO - PPB
For use with Dissolved Oxygen ppb Probes
TABLE I - OUTPUT CABLE
Cordset - 6m (19.7 ft.) - includes connector and cable -
Note 2
E
Field Wiring Connector
only
-
customer supplies cable only -
Note 2
TABLE II - SENSOR CABLE/REMOTE CONNECTOR (between electronic module and electrode, sensor or probe)
Integral Mounting
0
d d d d d
Remote Mounting
6,096m (20 ft.) of sensor cable - Durafet II Remote Mtg w/PWB connector
1
e
Cable -
6,096m (20 ft.) of sensor cable-Durafet III Remote Mtg w/Vario Pin connector-
Note 3
7
e
Durafet Only
15,24m (50 ft.) of sensor cable - Durafet II Remote Mtg w/PWB connector
e
15,24m (50 ft.) of sensor cable - Durafet III Remote Mtg w/Vario Pin connector-
Note 3
e
Remote Mounting
Remote Mounting Connector - Meredian II pH
e
Connector (Cable
Remote Mounting Connector - Meredian II ORP
e
is supplied with
Remote Mounting Connector - HPW7000
e
sensor or probe)
Remote Mounting Connector - Conductivity
e
Remote Mounting Connector - Dissolved Oxygen
e e
TABLE III - REMOTE MOUNTING OPTIONS
Mounting Kit for
None Integral unit - mounting not required
A
Remote Mounting
2" (5,08 cm) Pipe mtg. bracket, wall mtg, & DIN Rail clip
B
TABLE IV - OPTIONS
Tagging
None
00 _ _
SS Customer ID Tag - 3 lines w/22 characters/line
SS _ _
Certificates
None
_ _ 00
Calibration & Conformance
_ _ CC
3
3
No cable or connector required
Mounting
F
None
(replacement module or customer supplied output cable)-
Note 1
4
5
6
Availability
Output Cable for
Integral or Remote
DL425
D
2
8
Notes:
1
Customers may procure their own output cordsets from the vendors listed below.
2
Customers may make their own 4-20 mA output cordset using a 2-wire twisted shielded pair,
and M12 field wiring connector procured from one of the vendors listed below.
Use only UV rated outdoor cable to maintain NEMA 4 rating.
Phoenix Contact
Turck
Cordset
SAC-3P-5.0-PUR/M12FSSH Stainless
RKV4T-6/S618
M12 Field Wiring Connector
SACC-M12FS-4CON-PG7
B8141-0
Cable
3
Durafet III cables with Vario Pin connector require Durafet III electrode with Vario Pin connector
RESTRICTIONS
Table
d
e
ORDERING INSTRUCTIONS:
1. Part numbers are provided to facilitate Distributor Stock.
2. Orders may be placed either by model selection or by part number.
3. Part numbers are shown within the model selection tables to assist with compatibility information.
4. Orders placed by model selection are systematically protected against incompatibility.
5. Compatibility assessment is the responsibility of the purchaser for orders placed by part number.
6. Items labeled as N/A are not available via the stocking program and must be ordered by model selection.
2-wire twisted shielded pair
Restriction
Letters
Selection
Selection
III
B
Available Only With
Not Available With
IIl
A
Table
Содержание DirectLine DL421
Страница 34: ...Spare Parts 28 DirectLine DL421 Sensor Module User Manual 2 04 ...
Страница 35: ...Spare Parts 2 04 DirectLine DL421 Sensor Module User Manual 29 ...
Страница 37: ...Appendix CE Mark Applications 2 04 DirectLine DL421 Sensor Module User Manual 31 ...
Страница 39: ...2 04 DirectLine DL421 Sensor Module User Manual 33 ...