Table 1. TP970 Series CONVERTASTAT Kit Cross-Reference. 

Order No. 

Description 

Johnson 

Powers 

Robertshaw

Original 

Uni-line 

TP970A2145  Direct acting, single-temp, two-pipe, 60° to 90°F 

range. 

T4002-201 
T4002-203 

TH192-202 

TH192-200

T18-301 
T18-3011 

2212-118 
2212-128 

TP970A2242  Same as TP970A2145 except plastic cover is 

beige. 

T4002-6201 
T4002-6203 
T4101-1

T4101-6001

TH192-222

T12-301 
T12-3011 

2211-112

2211-012

2211-512

bd 

TP970A2234  Same as TP970A2145 except range is 15° to 

30°C. 

T4101-3

T4101-6003

TH192-220

— 

2212-518 

TP970B2077  Same as TP970A2145 except reverse acting. 

T4002-202 
T4002-204 

TH192-201

TH192-203 

T19-301 
T19-3011 

2212-119 
2212-129 

TP970B2166  Same as TP970B2077 except plastic cover is 

beige. 

T4001-2

T4001-6002

T4002-6202 

T4002-6204 

TH192-223

T13-301 
T13-3011 

2211-013 
2211-113 
2211-513

2212-519

TP970B2150  Same as TP970B2077 except range is 

15° to 30°C. 

T4001-4

T4001-6004

TH192-221

— 

— 

TP971A2102  Two-temp, two-pipe, 60° to 90°F (16° to 32°C) 

range, DAY and NITE setpoint knobs, 13/18 psi 
(90/124 kPa) changeover, field-adjustable to 
16/21 psi (110/145 kPa). 

T4506-201 
T4506-202 
T4506-203

T4506-204

T4506-6201 

T4506-6202 

TH192-204 

TH192-224

T23-301 
T23-3011 
T27-301 
T27-3011 

2214-121

2214-131

2216-126 
2216-136 
2216-526

TP971A2183  Same as TP971A2102 except plastic cover is 

beige. 

T4506-6203

T4506-6204

— 

— 

2214-521

TP972A2192  Single-temp, two-pipe, proportioning, 60 to 90°F 

(16 to 32°C) range, RA Summer 13 psi (90 kPa) or 
9 psi (62 kPa) unit vent, DA Winter 18 psi 
(124 kPa) changeover, field-adjustable. 

T4756-205 
T4756-206 
T4756-217 
T4756-6205 
T4756-6206 
T4756-6217 

TH192-208 
TH192-2082 
TH192-228

T32-301 
T32-3011 
T32-501 

2218-132 
2218-134 
2218-142 

2218-532

TP972A2200  Same as TP972A2192 except RA Summer 19 psi 

(131 kPa), DA Winter 14 psi (97 kPa) changeover. 

T4756-201 
T4756-207 
T4756-216 
T4756-6201 
T4756-6202 
T4756-6216 

TH194-2083  T33-301  2218-133 

a

For 2 in. x 2 in. thermostat mounted without 3 in. x 3 in. wall plate. 

b

Kit can be used only if two-pipe wall fitting installed originally. 

c

Use kit if DAY/NITE lever feature is acceptable. 

d

Original thermostat was part of a kit. 

e

Use kit if Fahrenheit scale is acceptable. 

Installation requires the following tools: 
— 1/16 in. Allen wrench. 
— 0.050 in. Allen wrench Thermostat Tool CCT735A. 
— Side cutters (diagonals) or knife to cut tubes. 
— Phillips screwdriver. 
— Standard screwdriver. 
— 5/32 in. tubing plug (optional), CCT1814 (plastic) or 

CCT1815 (aluminum). 

NOTE:   Honeywell Thermostat Tool Kit CCT3863 

includes thermostat Tool, thermostat key, and 
gage adapter. 

Fig. 2. Robertshaw Thermostat. 

ROBERTSHAW 

60 

70 

80 

50 

70 

90 

C2315 

85-0210EF—1

 

 

Содержание CONVERTASTAT TP970A2145

Страница 1: ...mponents needed to create a cover to meet building requirements are included INSTALLATION When the old mounting plate is removed retain the screws to use for mounting the adapter plate Cut the existing tubes as close as possible to the thermostat Do not remove the antikink springs from cut tubes Do not allow tubes to slip inside the wall after removing the old thermostat Remove Johnson Thermostat ...

Страница 2: ...3 3011 T27 301 T27 3011 2214 121c 2214 131c 2216 126 2216 136 2216 526d TP971A2183 Same as TP971A2102 except plastic cover is beige T4506 6203c T4506 6204c 2214 521d TP972A2192 Single temp two pipe proportioning 60 to 90 F 16 to 32 C range RA Summer 13 psi 90 kPa or 9 psi 62 kPa unit vent DA Winter 18 psi 124 kPa changeover field adjustable T4756 205 T4756 206 T4756 217 T4756 6205 T4756 6206 T4756...

Страница 3: ...s and separate see Fig 5 e Align and attach backplate and adapter plate to mounting screw holes using screws retained from stripping adapter plate threads f Proceed to Step 7 NOTE When adapting to a Johnson thermostat if wall holes are out of alignment with adapter plate holes use any available hole for an additional wall anchor HOLES 10 CODED PER MANUFACTURER J JOHNSON P POWERS R ROBERTSHAW TUBIN...

Страница 4: ...at 4 F 2 2 K and should not require any change under normal operating conditions If a change is necessary use following procedures to reset throttling range to values specified on job drawings NOTE Changing throttling range requires recalibration 1 Remove cover and install 0 to 30 psi 0 to 210 kPa gage with gage adapter in gage tap Fig 8 2 Slide throttling range adjustment to desired position on t...

Страница 5: ...reads approximately 10F 5 5C degrees above space temperature and set night setpoint dial below space temperature The gage should indicate main air pressure Push day auto lever to day left position it should stay there and BLP should go to 0 psi 0 kPa TP972 Turn setpoint adjustment until setpoint indicator reads approximately 10F 5 5C degrees above space temperature BLP should go to 0 psi 0 kPa 4 S...

Страница 6: ...Pa 4 Turn calibration screw in opposite direction until gage indicates 8 1 psi 56 7 kPa The thermostat is now calibrated 5 Remove gage and replace cover TP971 1 Remove cover and install a 30 psi 210 kPa gage into gage tap 2 Turn setpoint adjustment until setpoint indicator reads indicated temperature 3 With 13 psi 90 kPa day main air pressure turn day left calibration screw Fig 8 until gage indica...

Страница 7: ... notice explique comment retirer le thermostat selon le fabricant et installer le nouveau thermostat de série TP970 Une fois l ancienne plaque de montage retirée conserver les vis qui serviront à l installation de la plaque d adaptation Couper le tuyau existant aussi près que possible du thermostat Ne pas retirer des tuyaux le ressort antitortillement Ne pas laisser les tuyaux glisser à l intérieu...

Страница 8: ...e TP971A2102 mais avec couvercle de plastique beige T4506 6203c T4506 6204c 2214 521d TP972A2192 Une seule temp deux canalisations à action proportionnelle gamme de 60 à 90 F 16 à 32 C action inverse en été à 13 psi 90 kPa ou 9 psi 62 kPa ventilo convecteur action directe en hiver inversion à 18 psi 124 kPa réglable sur place T4756 205 T4756 206 T4756 217 T4756 6205 T4756 6206 T4756 6217 TH192 208...

Страница 9: ... plaque d adaptation et les fixer aux ouvertures des vis de montage à l aide des vis qui ont servi à aléser les filets de la plaque d adaptation f Passer à l étape 7 REMARQUE Lors du remplacement d un thermostat Johnson si les trous dans le mur ne corre spondent pas aux ouvertures de la plaque d adaptation utiliser n importe quel autre trou pour insérer une cheville additionnelle TROU DE GUIDAGE 2...

Страница 10: ...couvercle et installer un manomètre de 0 à 30 psi 0 à 210 kPa dans la prise de manomètre Fig 8 2 Faire glisser le curseur de la bande proportionnelle à la valeur désirée 3 Vérifier mécaniquement la bande proportionnelle en déplaçant le réglage du point de consigne jusqu à ce que la pression de la canalisation princi pale soit de 3 psi 21 kPa Prendre note du point de consigne 4 Déplacer ensuite le ...

Страница 11: ...uto à la position jour à gauche il devrait rester en position et la pression de la canalisation secondaire devrait passer à 0 psi 0 kPa TP972 Faire tourner le réglage du point de consigne jusqu à ce que l indicateur marque environ 10 F 5 5 C au dessus de la température ambiante La pression de la canalisation secondaire devrait passer à 0 psi 0 kPa B M S DU COUVERCLE DU FILTRE FILTRE DES ÉTAGES DU ...

Страница 12: ...opposé jusqu à ce que le manomètre indique 8 psi 1 psi 56 kPa 7 psi Le thermostat est maintenant étalonné 5 Retirer le manomètre et remettre le couvercle TP971 1 Retirer le couvercle et installer un manomètre de 30 psi 210 kPa dans la prise de manomètre 2 Faire tourner le réglage du point de consigne jusqu à ce que l indicateur du point de consigne marque la température indiquée 3 Avec une pressio...

Отзывы: