VISTA-40 Installation and Setup Guide
5-8
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*82
Non-Alarm Report Codes
(Second Digit
Enter
00-15
.
This field has ten two-digit entries as follows: Close, Open, Low Battery,
Low Battery Restore, AC Loss, AC Restore, Test, Power-up, Cancel, and
Program Tamper. Enter the report code
01-15
for each type of report.
Enter
00
for no report.
*83
First Test Report Time
Enter
00-07
the for day (01 = Monday)
Enter
00-23
for the hour
Enter
00-59
for the minutes
Enter the day and time that the first Test report shall be transmitted.
Enter
00
in all locations if the Test report is to be sent immediately upon
exiting. Enter
00
in the day location if the report is to be sent at the next
occurrence of the time that is set.
*84
Swinger Suppression (partition-
specific)
Enter
01-15
.
Enter
00
for unlimited reports
This option limits the number of messages (alarms or troubles) sent for a
specific zone in an armed period.
Must be
00
for UL installations.
*85
Enable Dialer Reports for Panics
& Duress (partition-specific)
0
= disable
1
= enable
This field has four entries as follows: Zone 95, 96, 99, and Duress. Enable
for each partition that the panics and duress reporting is desired.
NOTE:
Non-zero report code must be assigned to zone 92 to enable
Duress reporting.
Entering
1
allows a single 4208 to be set to zone numbers 10-17, but
precludes the use of any other polling loop devices.
Entering
0
allows all other configurations, such as no 4208, more than
one 4208, or other polling loop expansion present.
4208 Zone #s available when:
When *86 = 1 4208 DIP switches must be set to:
*86 = 1
*86 = 0
With word OFF
With word ON
10-17 10-16
sw 2 = ON
sw 2 = OFF
17-24
sw 3 = ON
sw 3 = OFF
25-32
sw 4 = ON
sw 4 = OFF
33-40
sw 5 = OFF
sw 5 = ON
41-48
49-56
Precludes use
of any other
polling loop
expansion
57-64
*86
4208 Module Zone Assignment
0
= other configurations
1
= 10-17 only
*87
Entry Warning (partition-specific)
0
= 3 short beeps
1
= slow continuous beeps
Select the type of warning for the entry delay period.
*88
Burglary Alarm Communicator
Delay (partition-specific)
0
= no delay
1
= 16-second delay
Select the delay, if any, for burglary alarm communications.
Must be
0
for UL installations.
*89
Restore Report Timing
0
= instant
1
= after bell timeout
2
= when system is disarmed
Select the time when restore reports are sent after an alarm.
Must be
2
for UL installations.
*90
Secondary Subscriber Account
Number (partition-specific)
Enter
00-09; B-F (11-15)
Enter a 3- or 4-digit (depending on report format) secondary subscriber
account number. Each number requires a 2-digit entry so as to allow
entry of hexadecimal digits (B-F). If a 3-digit account number is to be
used, enter data only in the first 3 locations, and enter * in the fourth
location.
NOTE:
This field
must
be programmed if a secondary phone number is
used (field *34). This account number can be the same as the primary
account number.
Содержание ADEMCO VISTA-40
Страница 1: ...N7001V5 5 04 Rev A 0 0 2 2 9 9 6 67 7 3DUWLWLRQHG 6HFXULW 6 VWHP QVWDOODWLRQ DQG 6HWXS XLGH ...
Страница 2: ...ii ...
Страница 10: ...VISTA 40 Installation and Setup Guide 2 2 ...
Страница 38: ...VISTA 40 Installation and Setup Guide 3 28 ...
Страница 46: ...VISTA 40 Installation and Setup Guide 4 8 ...
Страница 62: ...VISTA 40 Installation and Setup Guide 6 4 ...
Страница 64: ...VISTA 40 Installation and Setup Guide 7 2 ...
Страница 78: ...VISTA 40 Installation and Setup Guide B 2 ...
Страница 80: ...VISTA 40 Installation and Setup Guide C 2 ...
Страница 82: ...VISTA 40 Installation and Setup Guide D 2 ...
Страница 89: ...NOTES ...
Страница 90: ...NOTES ...
Страница 91: ...NOTES ...
Страница 92: ...NOTES ...
Страница 93: ...NOTES ...
Страница 94: ...NOTES ...
Страница 95: ...NOTES ...