ALPHA VOCABULARY LIST  (For Entering Zone Descriptors)

000

(Word Space)

– A –

• 001

AIR

• 002

ALARM

004

ALLEY

005

AMBUSH

• 006

AREA

• 007

APARTMENT

• 009

ATTIC

010

AUDIO

– B –

• 012

BABY

• 013

BACK

• 014

BAR

• 016

BASEMENT

• 017

BATHROOM

• 018

BED

• 019

BEDROOM

020

BELL

• 021

BLOWER

• 022

BOILER

023

BOTTOM

025

BREAK

• 026

BUILDING

– C –

028

CABINET

• 029

CALL

030

CAMERA

031

CAR

033

CASH

034

CCTV

035

CEILING

036

CELLAR

• 037

CENTRAL

038

CIRCUIT

• 040

CLOSED

• 046

COMPUTER

047

CONTACT

 

– D –

• 048

DAUGHTERS

049

DELAYED

• 050

DEN

051

DESK

• 052

DETECTOR

• 053

DINING

054

DISCRIMINATOR

055

DISPLAY

   

• 057

DOOR

• 059

DOWN

• 060

DOWNSTAIRS

061

DRAWER

• 062

DRIVEWAY

• 064

DUCT

– E –

• 065

EAST

066

ELECTRIC

067

EMERGENCY

068

ENTRY

• 069

EQUIPMENT

• 071

EXIT

072

EXTERIOR

– F –

• 073

FACTORY

075

FAMILY

• 076

FATHERS

• 077

FENCE

• 079

FIRE

• 080

FLOOR

081

FLOW

082

FOIL

• 083

FOYER

084

FREEZER

• 085

FRONT

– G –

• 089

GARAGE

• 090

GAS

091

GATE

• 092

GLASS

093

GUEST

094

GUN

– 

H –

• 095

HALL

• 096

HEAT

098

HOLDUP

099

HOUSE

100

INFRARED

• 101

INSIDE

102

INTERIOR

103

INTRUSION

– J –

104

JEWELRY

– K –

• 105

KITCHEN

   

– L –

• 106

LAUNDRY

• 107

LEFT

108

LEVEL

• 109

LIBRARY

• 110

LIGHT

111

LINE

• 113

LIVING

• 114

LOADING

115

LOCK

116

LOOP

117

LOW

• 118

LOWER

– M –

• 119

MACHINE

121

MAIDS

122

MAIN

• 123

MASTER

• 125

MEDICAL

126

MEDICINE

128

MONEY

129

MONITOR

• 130

MOTHERS

• 131

MOTION

132

MOTOR

– N –

• 134

NORTH

135

NURSERY

– O –

• 136

OFFICE

• 138

OPEN

139

OPENING

• 140

OUTSIDE

142

OVERHEAD

– P –

143

PAINTING

• 144

PANIC

145

PASSIVE

• 146

PATIO

147

PERIMETER

• 148

PHONE

150

POINT

151

POLICE

152

POOL

• 153

POWER

– R –

155

RADIO

• 156

REAR

157

RECREATION

159

REFRIGERATION

160

RF

• 161

RIGHT

• 162

ROOM

163

ROOF

– S –

164

SAFE

165

SCREEN

166

SENSOR

• 167

SERVICE

• 168

SHED

169

SHOCK

• 170

SHOP

171

SHORT

• 173

SIDE

174

SKYLIGHT

175

SLIDING

• 176

SMOKE

• 178

SONS

• 179

SOUTH

180

SPRINKLER

• 182

STATION

184

STORE

• 185

STORAGE

186

STORY

190

SUPERVISED

191

SUPERVISION

192

SWIMMING

193

SWITCH

– T –

194

TAMPER

196

TELCO

197

TELEPHONE

• 199

TEMPERATURE

200

THERMOSTAT

• 201

TOOL

202

TRANSMITTER

– U –

• 205

UP

• 206

UPPER

• 207

UPSTAIRS

• 208

UTILITY

– V –

209

VALVE

210

VAULT

212

VOLTAGE

– W –

213

WALL

214

WAREHOUSE

• 216

WEST

• 217

WINDOW

• 219

WING

220

WIRELESS

– X –

222

XMITTER

– Y –

223

YARD

– Z –

224

ZONE (No.)

• 225

ZONE

• 226

0

• 227

1

• 228

1ST

• 229

2

• 230

2ND

• 231

3

• 232

3RD

• 233

4

• 234

4TH

• 235

5

• 236

5TH

• 237

6

• 238

6TH

• 239

7

• 240

7TH

• 241

8

• 242

8TH

• 243

9

• 244

9TH

245

Custom Word #1

246

Custom Word #2

247

Custom Word #3

248

Custom Word #4

249

Custom Word #5

250

Custom Word #6

251

Custom Word #7

252

Custom Word #8

253

Custom Word #9

254

Custom Word #10

Note:

Bulleted (

) words in 

boldface  type

 are those that are also available for use by the 4285/4286 Phone Module. If

using a Phone module, and words other than these are selected for Alpha descriptors, the module will not provide
annunciation of those words.

CHARACTER (ASCII) CHART (For Adding Custom Words)

32 (space)
33

!

34

"

35

#

36

$

37

%

38

&

39

'

40

(

41

)

42

*

43

+

44

,

45

46

.

47

/

48

0

49

1

50

2

51

3

52

4

53

5

54

6

55

7

56

8

57

9

58

:

59

;

60

<

61

=

62

>

63

?

64

@

65

A

66

B

67

C

68

D

69

E

70

F

71

G

72

H

73

I

74

J

75

K

76

L

77

M

78

N

79

O

80

P

81

Q

82

R

83

S

84

T

85

U

86

V

87

W

88

X

89

Y

90 Z

Содержание Ademco VISTA-15PCN

Страница 1: ...7 3 9 67 3 1 3URJUDPPLQJ XLGH ON OFF 1 OFF 4 MAX 7 INSTANT READY 2 AWAY 5 TEST 8 CODE 0 3 STAY 6BYPASS 9CHIME ARMED READY 1 OFF 4 MAX 7INSTANT READY 2 AWAY 5 TEST 8 CODE 0 3 STAY 6BYPASS 9CHIME ARMED READY K5305 1PR 7 01 ...

Страница 2: ...umbers for 5800 RF transmitters 57 Function Key Programming Unlabeled keypad keys known as ABCD keys for special functions 58 Zone Programming Same options as 56 mode but with fewer prompts Intended for those familiar with Expert mode this type of programming otherwise 56 mode is recommended 79 Output Device Mapping Assign module addresses and map individual relays powerline carrier devices 80 Out...

Страница 3: ...IMING 31 39 31 ONE AUDIBLE ALARM PER ZONE 0 0 no UL must be 0 1 yes 32 FIRE ALARMSOUNDER TIMEOUT 0 0 sounder stops at timeout 1 no sounder timeout UL must be 1 for fire install 33 ALARM SOUNDER TIMEOUT 1 0 none 1 4 min 2 8 min 3 12 min 4 16 min UL minimum 1 4 min 34 EXIT DELAY 70 70 Part 1 Part 2 00 99 seconds of exit delay time for each partition Common zones use same delay as partition 1 35 ENTR...

Страница 4: ...ll 5 All All 50 15 SEC DIALER DELAY BURG 0 0 no UL must be 0 1 yes 53 SECOA RADIONICS SELECT 0 0 Radionics 0 9 B F 1 SESCOA 0 9 only reporting Select 0 for all other formats 54 DYNAMIC SIGNALING DELAY 0 Delay selectable from 0 to 225 secs in 15 sec increments 0 no delay both signals sent 1 15 secs 2 30 secs etc UL must be 0 55 DYNAMIC SIGNALING PRIORITY 0 0 Primary Dialer first 1 Long Range Radio ...

Страница 5: ...de 86 CANCEL VERIFY 0 0 no 1 yes 87 MISC FAULT DELAY TIME used with Configurable Zone Types digit 6 0 0 15 seconds 6 2 1 2 min 12 8 min 1 30 seconds 7 3 min 13 10 min 2 45 seconds 8 4 min 14 12 min 3 60 seconds 9 5 min 15 15 min 4 90 seconds 10 6 min 5 2 minutes 11 7 min UL may only be used on non burglar alarm non fire alarm zones when used in fire and or UL burglar alarm installation 89 EVENT LO...

Страница 6: ...EPORTING OPTIONS 0 0 0 Part 1 Part 2 common See field 162 for reporting options Select for each partition use zone list 10 if using options 12 or 13 166 PAGER 3 PHONE No Enter up to 20 digits 0 9 11 12 13 2 second pause 167 PAGER 3 CHARACTERS Enter the optional prefix characters up to 16 digits 0 9 11 12 13 2 second pause 168 PAGER 3 REPORTING OPTIONS 0 0 0 Part 1 Part 2 common See field 162 for r...

Страница 7: ...o this zone type Enter the codes sequentially all 6 digits When entering digits moves cursor back moves forward Press when done to continue KEYPAD OPTIONS 190 196 NOTE Options for keypad address 16 are set by the factory and cannot be changed NOTE Each keypad must be assigned a unique address Keypads programmed with the same address will give unpredictable results 190 KEYPAD 2 ADDRESS 17 0 0 Parti...

Страница 8: ...ms when armed disarmed 1 don t show alarms when armed show alarms trbles faults when disarmed 3 never show any alarms trbles faults 0 no 4 power reset after fault by code OFF 12 verification see zone type 16 0 no 1 delay 1 2 delay 2 0 no 4 use exit delay 0 no 8 yes see note 2 Digit 7 fault display power reset verification Digit 8 entry delay 1 entry delay 2 exit delay interior zone type DIGIT 9 DI...

Страница 9: ...6 37 38 39 40 41 42 43 44 45 46 47 48 49 1 BR 50 1 BR 51 1 BR 52 1 BR 53 1 BR 54 1 BR 55 1 BR 56 1 BR 57 1 BR 58 1 BR 59 1 BR 60 1 BR 61 1 BR 62 1 BR 63 1 BR 64 1 BR 95 00 N A N A N A N A keypad 1 96 00 N A N A N A N A keypad 3 99 06 N A N A N A N A keypad NOTES Zone Type see chart on page 12 Input Type HW 1 zones 1 8 AW 2 zones 9 48 RF 3 zones 1 48 UR 4 zones 1 48 BR 5 zones 49 64 Response Time 0...

Страница 10: ... X10 Output No Module Addr Pos 1 4 Unit No Description Output No Module Addr Pos 1 4 Unit No Description 01 09 02 10 03 11 04 12 05 13 06 14 07 15 08 16 17 On Board Trigger 1 18 On Board Trigger 2 81 ZONE LISTS FOR OUTPUT DEVICES Fill in the required data on the worksheet below and follow the procedure in the installation manual as you enter the data during the displays and prompts that appear in ...

Страница 11: ... 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 ZONE TYPE SYSTEM OPERATION Choices for Zone Types are 00 Not Used 05 Trouble Day Alarm Night 10 Interior w Delay 24 Silent Burglary 01 Entry Exit 1 06 24 Hr Silent 12 Monitor Zone 77 Keyswitch 02 Entry Exit 2 07 24 Hr Audible 14 Carbon Monoxide 90 93 Configurable 03 Perimeter...

Страница 12: ... central station and provides an alarm sound at the keypad and an audible external alarm Type 08 24 hour Auxiliary Alarm Assign to a zone containing an emergency button or to a zone containing monitoring devices such as water or temperature sensors Sends a report to the central station and provides an alarm sound at the keypad No bell output is provided Type 09 Fire Provides a fire alarm on short ...

Страница 13: ...eyswitch Types 90 93 Installer Defined These zone types can be programmed for various custom responses See data fields 182 185 UL Zone types 90 93 may not be used as fire or burglar zones in fire or UL burglar alarm installations The system can still be armed when these zone types are in a faulted condition Schedules installer code 6 4 master code can only access schedules 01 16 for VISTA 20P 01 0...

Страница 14: ...7 PERIMETER 148 PHONE 150 POINT 151 POLICE 152 POOL 153 POWER R 155 RADIO 156 REAR 157 RECREATION 159 REFRIGERATION 160 RF 161 RIGHT 162 ROOM 163 ROOF S 164 SAFE 165 SCREEN 166 SENSOR 167 SERVICE 168 SHED 169 SHOCK 170 SHOP 171 SHORT 173 SIDE 174 SKYLIGHT 175 SLIDING 176 SMOKE 178 SONS 179 SOUTH 180 SPRINKLER 182 STATION 184 STORE 185 STORAGE 186 STORY 190 SUPERVISED 191 SUPERVISION 192 SWIMMING 1...

Страница 15: ...w 5804BD ENROLL AS BR LOOP 3 LOOP 1 LOOP 2 LOOP 4 SET HOUSE CODE YOU MUST ENROLL THIS BUTTON LOOP 3 LOOP 1 LOOP 2 LOOP 4 YOU MUST ENROLL THIS BUTTON LOOP 1 5809 ENROLL AS RF LOOP 2 REED Table of Device Addresses Address Report Device Programmed by 00 100 RF Receiver 56 zone programming input device type entry 03 103 Long Range Radio automatic if output to long range radio field 29 enabled 04 104 4...

Страница 16: ... RING GRAY TIP GREEN RING RED INCOMING PHONE LINE HANDSET ZONE 1 ZONE 2 HI LO HI LO ZONE 3 ZONE 4 HI LO HI LO ZONE 5 ZONE 6 HI LO HI LO ZONE 7 ZONE 8 HI LO HI LO MAXIMUM LOOP RESISTANCE EACH ZONE 300 OHMS PLUS EOLR RESPONSE ZONES 1 8 10 350 OR 700 MSEC PROGRAMMABLE 8 PIN CONNECTOR USED FOR 4300 1321X10 TRANSFORMER CONNECTIONS AND FOR ON BOARD TRIGGERS SEE INSTRUCTIONS 7 8 USE SA4120XM 1 CABLE TIP ...

Отзывы: