13
–
Type 21
Arm-Away
•
Arms the system in Away mode when the zone is activated.
•
Pushbutton units send the user number to the central station when arming or disarming.
•
User code for button must be assigned.
Type 22
Disarm
•
Disarms the system when the zone is activated.
•
User code for button must be assigned.
Type 23*
No Alarm Response
•
Can be used on a zone when an output relay action is desired, but with no accompanying alarm (e.g.,
lobby door access).
Type 24
Silent Burglary
•
Usually assigned to all sensors or contacts on exterior doors and windows where bells and/or sirens are
NOT desired.
•
Provides an instant alarm, with NO audible indication at any keypad or external sounder, if the zone is
faulted when the system is armed in the Away, Stay, or Instant, modes.
•
A report is sent to the central station.
Type 77
Keyswitch
•
Assign to zone wired to a keyswitch.
Types 90-93
Installer Defined
•
These zone types can be programmed for various custom responses. See data fields *182-*185.
UL: Zone types 90-93 may not be used as fire or burglar zones in fire or UL burglar alarm installations.
*
The system can still be armed when these zone types are in a faulted condition.
Schedules
(installer code + [#] + [6] [4];
master code can only access schedules 01-16 for VISTA-20P, 01-04 for VISTA-15P, and
events 00-07 for both controls; VISTA-15P supports up to 8 schedules, VISTA-20P supports up to 32 schedules )
No.
Event
Device No.
Group No.
Partition
Start Time/
Stop Time/
Repeat
Random
(see list below)
for “01” events:
for “02” events:
for “04-06” events:
Days
Days
(yes/no)
(yes/no)
enter 01-18
enter 1-8
enter 1, 2, or 3
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Events:
Master/Installer
Installer Only
01 = device on/off
05 = forced AWAY arm
10 = display custom words 8-10
02 = user access
06 = auto disarm
11 = peridoic test report
03 = latch key report
07 = display “reminder”
04 = forced STAY arm