11
–
✱
80 OUTPUT DEFINITIONS
Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you
enter the data during the displays and prompts that appear in sequence.
Notes:
1.
For Relays, 4229 and 4204 devices are programmed in *79, *80, and *81 modes.
2.
For Powerline Carrier devices (plcd), field
✱
27 must be programmed with a House Code.
3
. Tampers of expansion units cannot be used to operate devices.
Activation Type and Detail
Event (for zone list/activated by)
Output
Function
Number
(V20P=1-48)
(V15P=1-24)
Activated by
0=delete
1=zn list
2=zn type
3=zn no.
Zone List
(ZL)
1-8 = list
Zone Type
(ZT)
(see table
below)
Zone No.
(ZN)
00=none
01-64
Partition
Number
(P)
(if using ZT trig)
0 = any
1 = partition 1
2 = partition 2
3 = common
By Zone List
0 = restore
1 = alarm
2 = fault
3 = trouble
By Zone No.
0 = restore
1 = alrm/flt/trbl
Action
0 = off
1 = close 2 secs
2 = stay closed
3 = pulse
4 = toggle
5 = duration 1
††
6 = duration 2
††
Output
Number
V20P=1-18
V15P=1-8,
17, 18
Device
Type
R = relay
T = trigger
X = X10
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
ZONE TYPE/SYSTEM OPERATION – Choices for Zone Types are:
00 = Not Used
05 = Trouble Day/Alarm Night
10 = Interior w/Delay
24 = Silent Burglary
01 = Entry/Exit#1
06 = 24 Hr Silent
12 = Monitor Zone
77 = Keyswitch
02 = Entry/Exit#2
07 = 24 Hr Audible
14 = Carbon Monoxide
90-93 = Configurable
03 = Perimeter
08 = 24 Hr Aux
16 = Fire w/Verification
04 = Interior Follower
09 = Fire
23 = No Alarm Response
Choices for System Operation are:
20 = Arming–Stay
38 = Chime
52 = Kissoff
21 = Arming–Away
39 = Any Fire Alarm
54 = Fire Zone Reset
22 = Disarming (Code + OFF)
40 = Bypassing
58 = Duress
31 = End of Exit Time
41 = **AC Power Failure
60 = AAV Trigger
32 = Start of Entry Time
42 = **System Battery Low
66 = Function key†
33 = Any Burglary Alarm
43 = Communication Failure
67 = Bell Failure
36 = **At Bell Timeout***
68 = TELCO Line Fault
78 = keyswitch red LED†††
79 = keyswitch green LED†††
Note:
In normal operation mode:
Code + # + 7 + NN Key Entry
starts
Device
Code + # + 8 + NN Key Entry
stops
Device
** Use 0 (any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
† Use *57 Menu mode to assign the function key.
†† Duration is set in program field *177.
††† Device action not used for these choices.