background image

Honeywell Sensing and Control     

3

Enclosed Basic Series Limit Switches

ISSUE 5

  

 

88173

WIRING

•  Honeywell’s Enclosed Basic Switches have internal terminals 

that allow for easy wiring and integration.

•  If a side mounting switch is being wired it is possible for the 

switch to be mounted in place before wiring takes place. If 
a flange mounting switch is being used it is likely that that 
the switching and actuator assembly will need to be wired 
before mounting switch.  

The enclosed basic series switch will have one of two contact 
forms available. They will either have a single pole double throw 
(SPDT) or a double pole double throw (DPDT) arrangement. The 
SPDT uses three terminals to wire a set of Common (C), Normally 
Open (NO), and Normally Close (NC) contacts. 

•  Remove the cover or the flange base by loosening the two 

screws that secure it.

•  Once the cover of the flange base is removed the switch 

terminals will be exposed. Switch terminals will be labeled 
according to the contact they connect to. Please refer the 
terminal layout section for more information on circuit dia-
grams and terminal screw layout. 

•  Connect wire to terminals by loosening terminal screws, 

looping wire around the terminal screw shaft, and inside 
of the cup washer on SPDT models or looping wire around 
the terminal screw shaft and underneath locking washer on 
DPDT models. Then retighten terminal screws ensuring wires 
and connections are made.

•  Grounding Terminal, enclosed basic switches have an inter

-

nal grounding screw mounted inside the removable cover or 
flange base.  

•  Replace cover or flange base and retighten cover screws   

Standard Enclosed Basic Switch Terminal Layout

Single Pole Double Throw (SPDT)

Double Pole Double Throw (DPDT)

Содержание 88173

Страница 1: ...age of this document MOUNTING 1 Mount switches on flat rigid surface E6 Side Mounting Pattern 25 4 mm 1 00 in 2X CLEARANCE HOLE FOR 6 MOUNTING SCREW E6 SIDE MOUNTING V6 Flange Mounting Pattern 41 6 mm 1 63 in 2X Ø 4 3 mm 0 17 in MOUNTING HOLES V6 FLANGE MOUNTING G1 Side Mounting Pattern 31 0 mm 1 22 in 75 0 mm 2 95 in 2X Ø 5 5 mm 0 216 in MOUNTING HOLES G1 SIDE MOUNTING H1 Flange Mounting Pattern ...

Страница 2: ...or or basic switch is replaced the actuator may need adjustment to duplicate original switch operating point To adjust operating point remove lower seal band from base of seal boot Peel back seal boot to expose bushing With basic switch unoperated slowly turn bushing clockwise until basic switch op erates Do not turn further after operating click is heard Turn bushing back 1 2 turn Tighten jam nut...

Страница 3: ... Remove the cover or the flange base by loosening the two screws that secure it Once the cover of the flange base is removed the switch terminals will be exposed Switch terminals will be labeled according to the contact they connect to Please refer the terminal layout section for more information on circuit dia grams and terminal screw layout Connect wire to terminals by loosening terminal screws ...

Страница 4: ...PA41 N62 actuators rod lever 6PA140 E6 Q62 actuators rod lever 6PA62 N4 actuators manual button 6PA9 Q4 actuators manual button 6PA7 N18 actuators spring 6PA195 N18 actuators spring and bushing 6PA187 E6 Conduit seal 2PA1 2PA6 2PA16 Seal boot black elastomer 10PA2 Seal boot orange silicon 10PA1 Bottom cover E6 3PA13 E6 Bottom cover V6 3PA14 V6 Pilot light for BZG H 15LT1 Conduit Sealing Packets Pa...

Страница 5: ...cular purpose In no event shall Honeywell be liable for consequential special or indirect damages While we provide application assistance personally through our literature and the Honeywell web site it is up to the customer to determine the suitability of the product in the application Specifications may change without notice The information we supply is believed to be accurate and reliable as of ...

Страница 6: ...onics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Honeywell 2PA17 6PA104 6PA105 6PA106 6PA107 6PA108 6PA109 6PA111 6PA112 6PA113 6PA114 6PA115 6PA116 6PA117 6PA62 2PA6 6PA7 ...

Отзывы: