8 - 8
F - File Format:
Indicates the type of file format in which to save the image.
0F
KIM format
1F
TIFF binary
2F
TIFF binary group 4, compressed
3F
TIFF grayscale
4F
Uncompressed Binary
5F
Uncompressed grayscale
6F
JPEG image
(default)
7F
Outlined image
8F
BMP format
H - Height of Signature Capture Area:
In the example, the height of the area
to be captured is 1 inch, resulting in a value of H = 1/0.01 = 100. The value
for H is slightly larger, to accommodate some extra image capture area
outside of the signature capture box.
K - Gamma Correction:
Gamma measures the brightness of midtone values
produced by the image. You can brighten or darken an image using gamma
correction. A higher gamma correction yields an overall brighter image. The
lower the setting, the darker the image. A setting of 100 results in no
adjustment to the image.
(Default = 50K)
0K
Gamma correction off
50K
Apply gamma correction for brightening typical document image
nK
Apply gamma correction factor
n (n = 1-255)
R - Resolution of Signature Capture Area:
The number of pixels that the
imager outputs per each minimum bar width. The higher the value for R, the
higher the quality of the image, but also the larger the file size.
S - Bar Code Aspect Ratio:
The ratio of the bar code height to the narrow
element width. In the example, the narrow element width is .010 inches and
the bar code height is 0.400 inches, resulting in a value of S = 0.4/0.01 = 40.
W - Width of Signature Capture Area:
In the example, the width of the area
to be captured is 1.90 inches, resulting in a value of W = 1.9/0.01 = 190. The
value for W is slightly larger, to accommodate some extra image capture area
outside of the signature capture box.
X - Horizontal Bar Code Offset:
The horizontal ratio offset of the center of
the signature capture area, in multiples of the minimum bar width. In the
example, the horizontal offset is 0.
Y - Vertical Bar Code Offset:
The vertical offset of the center of the signature
capture area, in multiples of the minimum bar width. Negative numbers
indicate that the signature capture is above the bar code, and positive
numbers indicate that the area is below the bar code. In the example, the
horizontal offset is 0.70 inches, resulting in a value for Y = 0.7/0.01 = 70.
Содержание 5010
Страница 1: ...5X10 5X80 5010 80 5110 80 5310 80 User s Guide ...
Страница 54: ...4 26 ...
Страница 62: ...5 8 ...
Страница 68: ...6 6 ...
Страница 104: ...7 36 RSS Limited Default All RSS Limited Settings RSS Limited RSS Expanded Default All RSS Expanded Settings On Off ...
Страница 124: ...7 56 ...
Страница 152: ...10 6 ...
Страница 178: ...11 26 ...
Страница 182: ...12 4 ...
Страница 190: ...A 6 ...
Страница 191: ......
Страница 195: ...OCR Programming Chart a e d g c h t l Discard Save r ...
Страница 196: ...Programming Chart A C B F E D 1 0 2 3 ...
Страница 198: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 5X10 80 UG Rev C 4 12 ...
Страница 199: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Honeywell 5310 ...