Beep Polarity
Beep Polarity sets the idle and active states of the beeper signal. When set to
Active High
, the beeper sounds when the signal shifts from low to high. When
set to
Active Low
, the beeper sounds when the signal shifts from high to low.
If the beeper is enabled for a good read (see
1), the polarity change takes effect after the next successful decode or a power
cycle. If the beeper is disabled, a polarity change only takes effect after a power
cycle.
Default = Active Low.
Note: Beep Polarity sets the beeper signal voltage level to either high (Active
Low) or low (Active High). This will affect Beeper-Good Read settings. If
the beeper has been disabled, make sure it is not turned on accidentally
by a polarity change.
Good Read Delay
This sets the minimum amount of time before the imager can read another bar
code.
Default = No Delay.
Active High
* Active Low
*
No Delay
Short Delay (500 ms)
Medium Delay (1,000 ms)
Long Delay (1,500 ms)
Содержание 5010
Страница 1: ...5X10 5X80 5010 80 5110 80 5310 80 User s Guide ...
Страница 54: ...4 26 ...
Страница 62: ...5 8 ...
Страница 68: ...6 6 ...
Страница 104: ...7 36 RSS Limited Default All RSS Limited Settings RSS Limited RSS Expanded Default All RSS Expanded Settings On Off ...
Страница 124: ...7 56 ...
Страница 152: ...10 6 ...
Страница 178: ...11 26 ...
Страница 182: ...12 4 ...
Страница 190: ...A 6 ...
Страница 191: ......
Страница 195: ...OCR Programming Chart a e d g c h t l Discard Save r ...
Страница 196: ...Programming Chart A C B F E D 1 0 2 3 ...
Страница 198: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 5X10 80 UG Rev C 4 12 ...
Страница 199: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Honeywell 5310 ...