4 - 19
Output Sequence Overview
Require Output Sequence
When turned off, the bar code data will be output to the host as the Imager
decodes it. When turned on, all output data must conform to an edited sequence
or the Imager will not transmit the output data to the host device.
Note: This selection is unavailable when the Multiple Symbols Selection is
turned on.
Output Sequence Editor
This programming selection allows you to program the Imager to output data
(when scanning more than one symbol) in whatever order your application
requires, regardless of the order in which the bar codes are scanned. Reading
the
Default Sequence
symbol programs the Imager to the Universal values,
shown below. These are the defaults. Be
certain
you want to delete or clear all
formats before you read the
Default Sequence
symbol.
Note: To make Output Sequence Editor selections, you’ll need to know the code
I.D., code length, and character match(es) your application requires. Use
the Alphanumeric symbols (inside back cover) to read these options.
Note: You must hold the trigger while reading each bar code in the sequence.
To Add an Output Sequence
1. Scan the
Enter Sequence
2.
Code I.D.
on page A-1, find the symbology to which you want
to apply the output sequence format. Locate the Hex value for that symbol-
ogy and scan the 2 digit hex value from the Programming Chart (inside back
cover).
3.
Length
Specify what length (up to 9999 characters) of data output will be acceptable
for this symbology. Scan the four digit data length from the Programming
Chart. (Note: 50 characters is entered as 0050. 9999 is a universal num-
ber, indicating all lengths.) When calculating the length, you must count any
programmed prefixes, suffixes, or formatted characters as part of the length
(unless using 9999).
4.
Character Match Sequences
ASCII Conversion Chart (Code Page 1252)
value that represents the character(s) you want to match. Use the Program-
ming Chart to read the alphanumeric combination that represents the ASCII
characters. (99 is the Universal number, indicating all characters.)
5.
End Output Sequence Editor
Scan
F F
to enter an Output Sequence for an additional symbology, or
Save
to save your entries.
Содержание 5010
Страница 1: ...5X10 5X80 5010 80 5110 80 5310 80 User s Guide ...
Страница 54: ...4 26 ...
Страница 62: ...5 8 ...
Страница 68: ...6 6 ...
Страница 104: ...7 36 RSS Limited Default All RSS Limited Settings RSS Limited RSS Expanded Default All RSS Expanded Settings On Off ...
Страница 124: ...7 56 ...
Страница 152: ...10 6 ...
Страница 178: ...11 26 ...
Страница 182: ...12 4 ...
Страница 190: ...A 6 ...
Страница 191: ......
Страница 195: ...OCR Programming Chart a e d g c h t l Discard Save r ...
Страница 196: ...Programming Chart A C B F E D 1 0 2 3 ...
Страница 198: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 5X10 80 UG Rev C 4 12 ...
Страница 199: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Honeywell 5310 ...