Mounting and Connection Instructions Viewguard PIR / AM FAI
6.
Detection coverage
6.1
Area optics
(state of delivery)
:
for optimal operating sensitivity.
Important note for mounting heights of more than 3.00 m:
In case of mounting heights of 3.00 to 3.40 m, the close range
between 0 - 1.50 m cannot be monitored completely despite
the requirements for VdS systems of class C (see detection
coverage diagram on right side).
Please inform the operating company and insurers about this
fact.
As the case may be, the respective areas must be monitored
separately by appropriate means (such as a second
detector).
Lens splitting
22 zones at 5 levels
Opening angle
80° hor., 64° vert.
Range
8 / 11 / 13 / 15 m
The following diagrams refer to a
.
(2.20 m to 3.00 m)
- to 2.80 m:
0°
- from 2.80 m:
optional 3° downward
verify by walk test
6.1.1 Mounting height
6.1.2 Optics
6.1.3 Detection diagrams
Recommended
2.50 m
Permitted:
2.20 m to 3.40 m
ATTENTION!
Area optics with sneak-by guard
range setting of 15 m
6.1.3.1 Mounting height 2.50 m
Vertical inclination:
Horizonal detection coverage
40°
20°
10°
0°
10°
20°
30°
40°
30°
0
3m
6m
9m
3m
6m
9m
0
3m
6m
9m
12m
15m
Expected
direction
of motion
Fig. 2
Vertical detection coverage
2.5m
3m
12m
15m
0m
9m
6m
Fig. 3
Vertical detection coverage
Fig. 5
Fig. 4
0
3m
6m
9m
12m
3.2m
6.1.3.2 Mounting height 3.00 to 3.40 m
Vertical mounting inclination 3° downward.
Horizonal detection coverage
Mounting as per Fig. 7/2
40°
20°
10°
0°
10°
20°
30°
40°
30°
0
3m
6m
3m
6m
0
3m
6m
9m
12m
Expected
direction
of motion