HOMMY ENTERPRISE (XINHUI) CO., LTD.
Model: HM116
23 - 32
7
Plastic scrapper excessive
wear.
Cause supercool, and ice cream
dispensing not hard enough.
Regular replacement.
8
Do not install axis sleeve.
Damage main components.
Installed correctly.
9
Fixing bolt on throat block is
not tightening enough.
Cause material leaking from the
sides of throat block.
Screw again and tighten the fixing
bolts.
10
Press down RUN (ice cream
production) button when there
is water remaining in the
cylinder.
Ice cream freezing in cylinder,
and damage stirring shaft and
throat block, and the main
components.
Prohibit press refrigeration (ice cream
production) button if there is water
remaining in cylinder.
11
There is water remaining in
cylinder when ice cream
production procedure is
running.
Machine happens abnormal noise
in refrigeration (ice cream
production) procedure. After the
procedure, ice cream overrun is
0% and no ice cream dispensing.
To completely remove water from
cylinder.
To start defrost procedure working
when no ice cream dispensing out.
12
Ice cream mixture is full in
cylinder.
Ice cream overrun down to 0%,
and expansion tube is ejected.
Pour about 2.2 liters material into
hopper, close the expansion tube the
air intake, dispense out 5~6 pieces of
ice cream and then adjust the air
intake to the minimum.
13
Do not disinfect the plugs,
throat block fixing bolt with
drugs.
In heat treatment procedure,
some material the temperature
does not heat up and rise, and
leading to bacteria.
Thoroughly sterilize with alcohol and
other drugs.
14
Do not clean the hopper lid.
Leading to bacteria.
After cleaning, thoroughly sterilize
with alcohol and other drugs.
15
Do not check and clean the drip
tray inside the machine.
Cause machine internal leakage
and increase maintenance costs.
Check and clean the leaking material
from the transmission shaft.
If leaking material is too much and out
of normal, please replace the sealing
gaskets and the damaged component.
16
Do not clean the hands before
replacing expansion tube.
Components contaminated again
after finishing the heat treatment
procedure.
E. checking failed, almost all of
the resulting.
Expansion tube is the place mostly
caused bacteria, therefore must clean
the hands before using.
At work, but also disinfect with alcohol
spray.
TROUBLESHOOTING GUIDE
●
Troubleshooting guide (1):
No.
Trouble
Possible cause
Solution
1
Completely not
running, displays
①
Lack phase sequence.
②
Stirring shaft reverses rotation.
①
Check power supply and power cable.
②、③
Replace component.