![Hommy HM901 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/hommy/hm901/hm901_manual_2154613022.webp)
HOMMY ENTERPRISE (XINHUI) CO., LTD.
Model: HM116
21 - 32
5
)
Date setting menu
6
)
Hour setting menu (24 hours)
7
)
Minute setting menu
8
)
Week setting menu
10) Ice cream quantity summation
11)
Parameter
data
displaying
menu
for
temperature sensor, motor running current
(Press MODE button to go into the menu, press
STOP button to exit the menu.)
Parameter data table:
Hopper temperature sensor T1=10
℃
Cylinder temperature sensor T2=-5
℃
Motor current MA=3.0A
Ice cream dispensing quantity CON=1000
8. Warning message
When machine happens, the keyboard indicator
light flash, error message displaying on the
left-lower of the screen as follows:
9. Mixture level displaying
Under normal circumstance, when little mixture
in hopper, the mixture level indicator light flash, and
no
function
when
press
(RUN)
button,
(PASTEURIZING) button and (DEF) button.
10. Buzzer function
a) Beep sounds when press any operation button.
b) Beep sounds when warning message happens.
11: Lock keyboard function
In (RUN + DEF) procedure, press (RUN) button for
Error Code
Description
ERROR NO
:
01
Ice cream freezing in cylinder
(
supercool
)
ERROR NO
:
02
Motor current protection
ERROR NO
:
03
Refrigeration
system
high
pressure protection
ERROR NO
:
04
Hopper temperature sensor faulty
ERROR NO
:
05
Cylinder
temperature
sensor
faulty
ERROR NO
:
06
/
ERROR NO
:
07
/
ERROR NO
:
08
Phase sequence alarm
ERROR NO
:
09
/
06/09 10:15 ( Mon )
SETUP PAGE 06
←
DAY=09
06/09 10:15 ( Mon )
SETUP PAGE 07
←
HOUR=10
06/09 10:15 ( Mon )
SETUP PAGE 08
←
MINUTE=15
06/09 10:15 ( Mon )
SETUP PAGE 09
←
WEEK=Mon
06/09 10:15 ( Mon )
T1=10
T2= -5
MA=3.0
CON=1000
EXIT
←
06/09 10:15 ( Mon )
SETUP PAGE 10
←
CON=1000
RES
06/09 10:15 ( Mon )
CHECK
ERROR NO
:
02