![Hommy HM901 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/hommy/hm901/hm901_manual_2154613021.webp)
HOMMY ENTERPRISE (XINHUI) CO., LTD.
Model: HM116
20 - 32
Keyboard instruction
1. Switch on the machine (Stand by
mode)
Switch on the machine, date and time should be
shown on screen.
《
Month/Date Hour : Minute (Week)
》
(
Figure 1
)
2. STOP button
Switch on the machine, press (STOP) button to
stop the machine running at any mode, the
screen will resume to stand by mode.
3. RUN button
Press (RUN) button, machine will enter into ice
cream production procedure. In this procedure,
the indicator light flash, when ice cream is finished,
the light to be shining.
(
Figure 2
)
4. WASH button
Under stand by mode, press (WASH) button to
start mixer motor running, the indicator light flash
at the same time until this procedure finishes, this
procedure will run about 3 minutes and then stop
running automatically, at that time, the light
shining, press (STOP) button to quit, or wait for
about 3 minutes when this procedure stops
running automatically.
In mixing (cleaning), the screen displaying
as
follows:
(
Figure 3
)
5. Pre-cooling overnight button
Pre-cooling overnight procedure, the indicator light
flash at that time.
The screen displaying as follows:
(
Figure 6
)
Note: If there is little mixture in hopper, then this
function does not work, at that that, the mixture
level indicator light shining, and the screen
displaying (Not ready).
6. MODE /
【
▲
】
/
【
▼
】
button
Press (MODE) button to enter into mode setting
menu, and press
【
▲
】
/
【
▼
】
button to display
setting items
①
-
⑩
on the screen, press again
(MODE) button, symbol “
←
” displays, move it to
select setting item as needs, press again
【
▲
】
/
【
▼
】
button to adjust parameter setting as request. When
finish setting, press (STOP) button to save and quit.
1
)
Ice cream hardness setting menu
(
parameter available: 18~80
)
2
)
pre-cooling temperature setting menu
(
parameter available: 1~15
)
3
)
Year setting menu
4
)
Month setting menu
06/09 10:15 ( Mon )
Stop
06/09 10:15 ( Mon )
Cooling
06/09 10:15 ( Mon )
Cleaning
06/09 10:15 ( Mon )
Heating(keep fresh)
06/09 10:15 ( Mon )
SETUP PAGE 01
←
S/H=30
06/09 10:15 ( Mon )
SETUP PAGE 02
←
TEMP=09
06/09 10:15 ( Mon )
SETUP PAGE 04
←
YEAR=2014
06/09 10:15 ( Mon )
SETUP PAGE 05
←
MONTH=06