26
9
the fixing nuts of throat block are
not tightened.
it cause leaking slurry from
the side of throat block.
tighten the fixing nuts
10
click on the refrigeration icon
when the cylinder is full of water.
the water is frozen in the
cylinder, which results in
damaging the main parts
such as stirring shaft and so
on.
do not click on the refrigeration icon
when the cylinder is full of water.
11
when it is in material feeding
program, the water in cylinder
can not drain completely.
When it is in refrigeration
program,
it
makes
the
noises. After refrigeration,
ice cream is not puffed and
may not drain out.
The water should be drained out
completely. If ice cream can’t drains
out, it should be thawed until it can
drain out. As the ice cream can
drain out , you should click on
refrigeration icon to make the ice
cream frozen again. After you make
several cups of ice cream, the
material feeding program should
stop.
12
when the cylinder is full of slurry,
the
machine
enters
into
refrigeration program.
the puffing rate of ice cream
is 0%, and the ice cream
flows out from the gravity
pipe.
you should pour 1.2L slurry and
then install the gravity pipe with
closed hole. After refrigeration, you
can open the small,middle or large
hole which depends on the selling
speed.
13
do not disinfect the plugs, throat
block, nuts and so on.
When it is in pasteurization
program, the temperature of
these parts can not be
warming, which accelerates
bacterial reproduction.
Use the disinfectant to sterilize.
14
do not clean the hopper lids
thoroughly.
it
accelerates
bacterial
reproduction.
After washing the lids, you should
use the disinfectant to sterilize such
as ethyl alcohol.
15
do not check and clean the sink.
You can not discover that
the
slurry
leaks
from
transmission shaft, which
leads to leaking inside the
machine and costs much
money on maintenance.
Check it every day and clean the
sink. If the slurry leaks more than
what the rules allowed, you should
replace the circle gaskets in the
cylinder.
16
do not wash the hands before
you replace the gravity pipe.
this will pollute the parts
which have been sterilize.
And
it
also
result
in
disqualification
on
Escherichia coli.
It is easier to be polluted by bacteria
on gravity pipe. So, people who
operate the machine must wash
their hands thoroughly and sterilize
by alcohol.