6
NEW CONSTRUCTION ASSEMBLY INSTRUCTIONS
NEW CONSTRUCTION – ATTACHING TO THE
JOIST
BEFORE INSTALLATION
Turn off power source. Review all safety precautions.
1. Place the fan housing (A) next to a ceiling joist
or wall stud. The fan housing should be level and
perpendicular to the joist or stud. Allow for thick-
ness of ceiling board used in your application.
DO NOT flush mount to joist. Bottom of fan (A)
should be flush with ceiling board.
2. If needed before mounting the fan housing to
the joist, remove the plastic duct connector for
easier access to the mounting hole on the fan
body.
Remove the duct connector by inserting a flat
head screw driver between the plastic and metal
of the housing, then GENTLY pry the duct
connector off.
3. Mount fan body to the joist or stud using long
wood screws (AA) where indicated by arrows
outside fan housing (A).
Hardware Used
AA
Long wood screws
x 2
1
2
1
www.homewerksww.com
2
3