FAN – LIMITED 3-YEAR WARRANTY
If the fan fails due to a defect in materials or workmanship at any time during the first THREE years of ownership, the manufacturer will replace it free of
charge, postage-paid at their option. This warranty does not cover products that have been abused, altered, damaged, misused, cut or worn. This warranty
does not cover use in commercial applications. Use only manufacturer-supplied genuine warranty repair replacement parts to repair this fan. Use of
non-genuine repair parts will void your warranty. The manufacturer DISCLAIMS all other implied or express warranties including all warranties of
merchantability and/or fitness for a particular purpose. As some states do not allow exclusions or limitations on an implied warranty, the above exclusions
and limitations may not apply. This warranty gives you specific legal rights, and you may have other rights that vary from state to state.
This warranty is limited to the replacement of defective parts only. Labor charges and/or damage incurred during installation, repair, replacement as well
as incidental and consequential damages connected with the above are excluded. Any damage to this product as a result of neglect, misuse, accident,
improper installation or use other than the purpose SHALL VOID THIS WARRANTY.
Shipping costs for return product as part of a claim on the warranty must be paid for by the customer.
Inquiries regarding warranty claims can be directed to 1-877-319-3757, 8 a.m. - 5 p.m., CST, Monday - Friday.
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
The fan seems louder than
it should
CFM too great
Be sure the CFM rating on the fan matches the
size of your room.
Damper not working properly or damaged
Check damper to ensure it is opening and closing
properly. If the damper has become damaged,
please call Customer Service.
Bend in duct too close to fan discharge
Be sure you do not have any sharp bends in duct
closer than 18 in. to the fan discharge.
Fan discharge reduced to fit smaller duct
Use recommended size ducting to reduce fan noise.
Fan body not securely attached
Be sure the fan is securely attached to your ceiling
joists.
The fan is not
clearing the room
Insufficient intake airflow within room
Be sure a door or window is slightly ajar or opened
to allow airflow. The fan is not able to draw air out of
the room without enough airflow to draw from.
Insufficient CFM
Be sure the CFM rating on the fan matches the
requirements for your room size.
NOTE: Using a tissue is not an accurate method
for determining if the fan is operating properly. If the
fan clears steam from the room within approximately
15 minutes of completing your shower, then the fan
is operating properly.
CARE AND MAINTENANCE
See safety information before proceeding. Routine maintenance should be done at least once a year.
Turn off power source. Review all safety precautions.
• Never use solvents, thinner or harsh chemicals for cleaning the fan.
• Do not allow water to enter the motor.
• Do not immerse metal parts in water.
• Do not immerse resin parts in water over 140 degrees Fahrenheit.
2
2. Choose which finial finish suits your application.
Place rubber spacer (BB) on the LED light kit
threaded rod. Then place the glass globe on to
the rod. Finally place the chosen finial on the
rod and tighten into place with the matching
finial nut.
Hardware Used
BB
Rubber spacer
x 1
NOTE:
Glass globe should not be mounted less
than 2.0 cm from the ceiling board.
BB