18
2.
Locate the wiring ports on the left side of the Control Valve (1) head base plate. Remove
the valve cover. If you are using the optional Forward Flush Kit (
UP-FF
), there will be 2
ports, otherwise, there will be only one. The port in the front of the valve is for the back
flush solenoid and the one in the back is for the forward flush solenoid. The wire(s) from
the solenoid control box(es) will be secured to the control valve with a cable gland and nut.
These parts are shipped attached to the wire from the solenoid wiring kit control box.
3.
For each solenoid, insert the wire upwards through the Control Valve (1) head base plate,
allowing the threaded end of the cable gland to insert through the hole. Use the gland nut
to secure the cable gland as shown below.
4.
Loosen the cable gland(s) so that you can extend the wire(s) forward to the bottom left
corner of the touch screen control panel and circuit board. Note the location of the
opening in the backplate which can be used to easily pass the wire from the forward flush
solenoid control box through to the front of the valve.